Multiple-pinhole collimators improve intra- and between-rater agreement and the certainty of the visual interpretation in dopamine transporter SPECT
Multiple-pinhole collimators improve intra- and between-rater agreement and the certainty of the visual interpretation in dopamine transporter SPECT
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Publication status: preprint
A plain-language reading has not been prepared for this paper yet.
Original abstract
Abstract Background: Multiple-pinhole (MPH) collimators improve the resolution-sensitivity tradeoff compared to parallel-hole collimators. This study evaluated the impact of MPH collimators on intra- and between-rater agreement, and on the certainty of visual interpretation in dopamine transporter (DAT)-SPECT.Methods: The study included 71 patients (62.1±12.7y). Two SPECT acquisitions were performed in randomized order after a single injection of 182±9MBq 123I-FP-CIT, one with MPH and one with low-energy-high-resolution-high-sensitivity (LEHRHS) collimators. MPH projections were reconstructed with an iterative 3d Monte Carlo algorithm. LEHRHS projections were reconstructed with filtered backprojection (FBP) or with ordered-subsets-expectation-maximization and resolution recovery (OSEM). Images were visually evaluated twice by three independent raters with respect to presence/absence of Parkinson-typical reduction of striatal 123I-FP-CIT uptake using a Likert 6-score (-3=clearly normal, …, 3=clearly reduced). In case of intra-rater discrepancy, an intra-rater consensus was obtained. Intra- and between-rater agreement with respect to the Likert score (full score and dichotomized score) were characterized by Cohen’s kappa. Results: Intra-rater kappa of visual scoring of MPH/LEHRHS-OSEM/LEHRHS-FBP images was 0.84±0.12/0.73±0.06/0.73±0.08 (full score, mean of three raters) and 1.00±0.00/0.96±0.04/0.97±0.03 (dichotomized score). Between-rater kappa of visual scoring (intra-rater consensus) of MPH/LEHRHS-OSEM/LEHRHS-FBP images was 0.70±0.06/0.63±0.08/0.48±0.05 (full score, mean of three pairs of raters) and 1.00±0.00/0.92±0.04/0.90±0.06 (dichotomized score). There was a decrease of (negative) Likert scores in normal DAT-SPECT by 0.87±0.18 points from the LEHRHS-OSEM to the MPH setting. The (positive) Likert scores of reduced DAT-SPECT did not change on average.Conclusions: MPH collimators improve intra- and between-rater agreement as well as the certainty of the visual interpretation of DAT SPECT.