RESEARCH / DISCOVERY
← Back to the library

An Automatic Evaluation Method for Parkinson's Dyskinesia Using Finger Tapping Video for Small Samples

An Automatic Evaluation Method for Parkinson's Dyskinesia Using Finger Tapping Video for Small Samples

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Explore research worldwide

Publication status: preprint

A plain-language reading has not been prepared for this paper yet.

Original abstract

Abstract PurposeThe assessment of dyskinesia in Parkinson's disease (PD) based on Artificial Intelligence technology is a significant and challenging task. At present, doctors usually use MDS-UPDRS scale to assess the severity of patients. This method is time-consuming and laborious, and there are subjective differences. The evaluation method based on sensor equipment is also widely used, but this method is expensive and needs professional guidance, which is not suitable for remote evaluation and patient self-examination. In addition, it is difficult to collect patient data in medical research, so it is of great significance to find an objective and automatic assessment method for Parkinson's dyskinesia based on small samples.MethodsIn this study, we design an automatic evaluation method combining manual features and convolutional neural network (CNN), which is suitable for small sample classification. Based on the finger tapping video of Parkinson's patients, we use the pose estimation model to obtain the action skeleton information and calculate the feature data. We then use the 5-folds cross validation training model to achieve optimum trade-of between bias and variance, and finally make multi-class prediction through fully connected network (FCN). ResultsOur proposed method achieves the current optimal accuracy of 79.7% in this research. We have compared with the latest methods of related research, and our method is superior to them in terms of accuracy, number of parameters and FLOPs. ConclusionThe method in this paper does not require patients to wear sensor devices, and has obvious advantages in remote clinical evaluation. At the same time, the method of using motion feature data to train CNN model obtains the optimal accuracy, effectively solves the problem of difficult data acquisition in medicine, and provides a new idea for small sample classification.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE