RESEARCH / DISCOVERY
← Back to the library

Absolute quantitation of sympathetic nerve activity using 123I-metaiodobenzylguanidine SPECT-CT in neurology

Absolute quantitation of sympathetic nerve activity using 123I-metaiodobenzylguanidine SPECT-CT in neurology

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Explore research worldwide

Publication status: preprint

A plain-language reading has not been prepared for this paper yet.

Original abstract

Abstract Objective The ability of 123I- metaiodobenzylguanidine (MIBG) sympathetic nerve imaging with three-dimensional (3D) quantitation to clinically diagnose neurological disorders has not been evaluated. This study compared absolute heart counts calculated as mean standardized uptake values (SUVmean) with conventional planar image-based quantitation and assessed the contribution of 123I-MIBG single-photon emission computed tomography (SPECT)-CT to the diagnosis of neurological diseases. Methods Seventy-two patients with neurological diseases were consecutively assessed using early and delayed 123I-MIBG SPECT-CT and planar imaging. Left ventricles were manually segmented in both early and delayed SPECT-CT images, and SUVmean and washout rates (WRs) were calculated. Heart-to-mediastinum ratios (HMRs) and WRs on planar images were conventionally computed. We investigated correlations between planar HMRs and SPECT-CT SUVmeans and between WRs obtained from planar and SPECT-CT images. The cutoff for SPECT-CT WR was defined by linear regression together with normal values of planar WR from a database, and the classification was compared with neurological diagnoses of the patients. We classified the patients according to clinical diagnoses of neurological diseases as follows: controls (n = 6), multiple system atrophy (MSA, n = 7), progressive supranuclear palsy (PSP, n = 17), and Parkinson’s disease or dementia with Lewy bodies (PD/DLB, n = 19), then compared SPECT-CT and planar image parameters among them. Results We found significant correlations between SPECT-CT SUVmean and planar HMR on early and delayed images (R2 = 0.69 and 0.82, p < 0.0001) and between SPECT-CT and planar WRs (R2 = 0.79, p < 0.0001). When the threshold was 31% based on linear regression for SPECT-CT WR, planar and SPECT-CT WR agreed in 67 (93.1%) of 72 patients. Compared with controls, early and delayed SUVmean in patients with PSP and MSA tended more towards significance than planar HMR. This trend was similar for SPECT-CT WRs in patients with PSP. Conclusions Absolute heart counts and SUVmean determined using 123I-MIBG SPECT-CT correlated with findings of conventional planar images in patients with neurological diseases. Three-dimensional quantitation with 123I-MIBG SPECT-CT imaging might differentiate patients with PSP and MSA from controls.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE