Validation of IMU-based gait event detection during curved walking and turning in older adults and Parkinson's Disease patients

Validation of IMU-based gait event detection during curved walking and turning in older adults and Parkinson's Disease patients

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Explore research worldwide

Publication status: preprint

A plain-language reading has not been prepared for this paper yet.

Original abstract

Abstract Background: Identification of individual gait events is essential for clinical gait analysis, because it can be used for diagnostic purposes or tracking disease progression in neurological diseases such as Parkinson's disease. Previous research has shown that gait events can be detected from a shank-mounted inertial measurement unit (IMU), however detection performance was often evaluated only from straight-line walking. For use in daily life, the detection performance needs to be evaluated in curved walking and turning as well as in single-task and dual-task conditions. Methods: Participants (older adults, people with Parkinson's disease, or people who had suffered from a stroke) performed three different walking trials: 1) straight-line walking, 2) slalom walking, 3) Stroop-and-walk trial. An optical motion capture system was used a reference system. Markers were attached to the heel and toe regions of the shoe, and participants wore IMUs on the lateral sides of both shanks. The angular velocity of the shank IMUs was used to detect instances of initial foot contact (IC) and final foot contact (FC), which were compared to reference values obtained from the marker trajectories. Results: The detection method showed high recall, precision and F1 scores in different populations for both initial contacts and final contacts during straight-line walking (IC: recall = 100%, precision = 100%, F1 score = 100%; FC: recall = 100%, precision = 100%, F1 score = 100%), slalom walking (IC: recall = 100%,precision ≥ 99%, F1 score =100%; FC: recall = 100%, precision ≥ 99%, F1 score =100%), and turning (IC: recall ≥ 85%, precision ≥ 95%, F1 score ≥ 91%; FC: recall ≥ 84%, precision ≥ 95%, F1 score ≥ 89%). Conclusions: Shank-mounted IMUs can be used to detect gait events during straight-line walking, slalom walking and turning. However, more false events were observed during turning and more events were missed during turning. For use in daily life we recommend identifying turning before extracting temporal gait parameters from identified gait events.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE