Where did the research take place?

Possible study sites were matched from the text; these need review.

Bath, GB · Possible study site

We also performed tests in a saline bath to validate the recordings quality.
Location evidence

Explore research worldwide

Publication status: preprint

A plain-language reading has not been prepared for this paper yet.

Original abstract

ABSTRACT Background Technical advances in deep brain stimulation (DBS) are crucial to improve therapeutic efficacy and battery life. A prerogative of new devices is the recording and processing of a given input signal to instruct the delivery of stimulation. Objective We studied the advances and pitfalls of one of the first commercially available devices capable of recording brain local field potentials (LFP) from the implanted DBS leads, chronically and during stimulation. Methods We collected clinical and neurophysiological data of the first 20 patients (14 with Parkinson’s disease [PD], five with various types of dystonia, one with chronic pain) that received the Percept™ PC in our centers. We also performed tests in a saline bath to validate the recordings quality. Results The Percept PC reliably recorded the LFP of the implanted site, wirelessly and in real time. We recorded the most promising clinically useful biomarkers for PD and dystonia (beta and theta oscillations) with and without stimulation. Critical aspects of the system are presently related to contact selection, artefact detection, data loss, and synchronization with other devices. Furthermore, we provide an open-source code to facilitate export and analysis of data. Conclusion New technologies will soon allow closed-loop neuromodulation therapies, capable of adapting the stimulation based on real-time symptom-specific and task-dependent input signals. However, technical aspects need to be considered to ensure clean synchronized recordings. The critical use by a growing number of DBS experts will alert new users about the currently observed shortcomings and inform on how to overcome them.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE