RESEARCH / DISCOVERY
← Back to the library

Diagnostic Effectiveness of [123I]Ioflupane Single Photon Emission Computed Tomography (SPECT) in Multiple System Atrophy

Diagnostic Effectiveness of [123I]Ioflupane Single Photon Emission Computed Tomography (SPECT) in Multiple System Atrophy

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Explore research worldwide

Publication status: preprint

A plain-language reading has not been prepared for this paper yet.

Original abstract

Background: Multiple system atrophy (MSA) is a rapidly progressive neurodegenerative disorder that has no curative treatment. Diagnosis is based on a set of criteria established by Gilman (1998 and 2008) and recently updated by Wenning (2022). We aim to determine the effectiveness of [123I]Ioflupane SPECT in MSA, especially at the initial clinical suspicion. Methods: Cross-sectional study of patients at initial clinical suspicion of MSA, referred for [123I]Ioflupane SPECT. Results: 139 patients (68 men, 71 women) were included, 104 being MSA-probable and 35 MSA-possible. MRI was normal in 89.2% while SPECT was positive in 78.45%. SPECT showed high sensitivity (82.46%) and positive predictive value (86.24), reaching maximum sensitivity in MSA-P (97.26%). Significant differences were found when relating both SPECT assessments in the healthy-sick and inconclusive-sick groups. We also found an association when relating SPECT to the subtype (MSA-C or MSA-P), as well as to the presence of parkinsonian symptoms. Lateralization of striatal involvement was detected (left side). Conclusions: [123I]Ioflupane SPECT is a useful and reliable tool for diagnosing MSA, with good effectiveness and accuracy. Qualitative assessment shows a clear superiority when distinguishing between the healthy-sick categories, as well as between the parkinsonian (MSA-P) and cerebellar (MSA-C) subtypes at initial clinical suspicion.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE