RESEARCH / DISCOVERY
← Back to the library

Comparative Utility of the BESTest, Mini-BESTest, and Brief-BESTest for Predicting Falls in Individuals With Parkinson Disease: A Cohort Study

Comparative Utility of the BESTest, Mini-BESTest, and Brief-BESTest for Predicting Falls in Individuals With Parkinson Disease: A Cohort Study

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

GB · Author affiliation · country only

J.T. Cavanaugh, PT, PhD, Department of Physical Therapy, University of New England, Portland, Maine.
Location evidence

US · Author affiliation · country only

G.M. Earhart, PT, PhD, Program in Physical Therapy, Department of Anatomy & Neurobiology, and Department of Neurology, Washington University School of Medicine, Campus Box 8502, 4444 Forest Park Blvd, St Louis, MO 63108 (USA).
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BackgroundThe newly developed Brief–Balance Evaluation System Test (Brief-BESTest) may be useful for measuring balance and predicting falls in individuals with Parkinson disease (PD).ObjectivesThe purposes of this study were: (1) to describe the balance performance of those with PD using the Brief-BESTest, (2) to determine the relationships among the scores derived from the 3 versions of the BESTest (ie, full BESTest, Mini-BESTest, and Brief-BESTest), and (3) to compare the accuracy of the Brief-BESTest with that of the Mini-BESTest and BESTest in identifying recurrent fallers among people with PD.DesignThis was a prospective cohort study.MethodsEighty participants with PD completed a baseline balance assessment. All participants reported a fall history during the previous 6 months. Fall history was again collected 6 months (n=51) and 12 months (n=40) later.ResultsAt baseline, participants had varying levels of balance impairment, and Brief-BESTest scores were significantly correlated with Mini-BESTest (r=.94, P<.001) and BESTest (r=.95, P<.001) scores. Six-month retrospective fall prediction accuracy of the Brief-BESTest was moderately high (area under the curve [AUC]=0.82, sensitivity=0.76, and specificity=0.84). Prospective fall prediction accuracy over 6 months was similarly accurate (AUC=0.88, sensitivity=0.71, and specificity=0.87), but was less sensitive over 12 months (AUC=0.76, sensitivity=0.53, and specificity=0.93).LimitationsThe sample included primarily individuals with mild to moderate PD. Also, there was a moderate dropout rate at 6 and 12 months.ConclusionsAll versions of the BESTest were reasonably accurate in identifying future recurrent fallers, especially during the 6 months following assessment. Clinicians can reasonably rely on the Brief-BESTest for predicting falls, particularly when time and equipment constraints are of concern.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE