RESEARCH / DISCOVERY
← Back to the library

Gait event prediction from surface electromyography in parkinsonian patients

Gait event prediction from surface electromyography in parkinsonian patients

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Berlin, DE · Author affiliation

Uncertainty, Inverse Modeling and Machine Learning Group, Technical University of Berlin, Berlin, Germany
Location evidence

Braunschweig, DE · Author affiliation

Mathematical Modelling and Data Analysis Department, Physikalisch-Technische Bundesanstalt Braunschweig und Berlin, Berlin, Germany
Location evidence

Würzburg, DE · Author affiliation

Department of Neurology, University Hospital of Würzburg and The Julius Maximilian University of Würzburg, Würzburg, 97080, Germany
Location evidence

Centro, IT · Author affiliation

Centro Parkinson, ASST Gaetano Pini-CTO, Milano, Italy
Location evidence

Milan, IT · Author affiliation

Centro Parkinson, ASST Gaetano Pini-CTO, Milano, Italy
Location evidence

Explore research worldwide

Publication status: preprint

A plain-language reading has not been prepared for this paper yet.

Original abstract

Gait disturbances are common manifestations of Parkinson’s disease (PD), with unmet therapeutic needs. Inertial measurement units (IMU) are capable of monitoring gait, but they lack neurophysiological information that may be crucial for studying gait disturbances in these patients. Here, we present a machine-learning approach to approximate IMU angular velocity profiles, and subsequently gait events from electromyographic (EMG) channels. We recorded six parkinsonian patients while walking for at least three minutes. Patient-agnostic regression models were trained on temporally-embedded EMG time series of different combinations of up to five leg muscles bilaterally (i.e., tibialis anterior, soleus, gastrocnemius medialis, gastrocnemius lateralis, and vastus lateralis). Gait events could be detected with high temporal precision (median displacement <50 msec), low numbers of missed events (<2%), and next to no false positive event detections (<0.1%). Swing and stance phases could thus be determined with high fidelity (median F1 score ∼0.9). Interestingly, the best performance was obtained using as few as two EMG probes placed on the left and right vastus lateralis. Our results demonstrate the practical utility of the proposed EMG-based system for gait event prediction while allowing the simultaneous acquisition of an electromyographic signal. This gait analysis approach has the potential to make additional measurement devices such as IMU and force plates less essential, and thereby to reduce financial and preparation overheads and discomfort factors in gait studies.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE