RESEARCH / DISCOVERY
← Back to the library

Real-Time and Real-World Gait Monitoring on a Wearable Device: A Fully Embedded System for Parkinson’s Disease

Real-Time and Real-World Gait Monitoring on a Wearable Device: A Fully Embedded System for Parkinson’s Disease

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Explore research worldwide

Publication status: preprint

A plain-language reading has not been prepared for this paper yet.

Original abstract

Abstract Background: Real-time gait analysis is essential for capturing transient gait alterations as they occur, enabling assessment of mobility beyond delayed retrospective analysis. This capability is particularly relevant in Parkinson’s disease (PD), where gait characteristics fluctuate throughout daily activities and may benefit from continuous monitoring. However, many existing gait analysis systems rely on offline processing or laboratory-based equipment, limiting their applicability for long-term real-world monitoring.This study aims to develop and validate a wearable, foot-worn sensor system that enables real-time, on-device gait analysis suitable for long-term monitoring of activities of daily living in patients with PD. Methods: We developed a two-stage algorithm consisting of motion detection followed by gait event detection. Algorithm parameters were optimized using four-fold cross-validation on home recordings of 28 individuals with PD (FallRiskPD), replayed as a simulated real-time data stream. The finalized system was subsequently validated under true real-time conditions on an independent dataset of 18 healthy participants (TestES), performing supervised, instructed, and self-directed walking tasks, validating end-to-end system operation including wireless data transmission and real-time gait parameter delivery. Results: The hardware achieved an F1-score of 85.4% for stride segmentation on home recordings from patients with PD. Relative to a state-of-the-art offline reference method, temporal gait parameters had an absolute percentage error of 0.3% for stride time, 6.5% for swing time, and 3.6% for stance time. Under true real-time evaluation of the complete end-to-end system, the implementation achieved an average runtime of 1.245 ± 0.578 ms per update, with a mean parameter-delivery delay of 1.169 ± 0.525 ms using 3-second analysis windows, demonstrating continuous real-time operation. Conclusions: This work presents a portable real-time gait analysis system with fully embedded processing for wearable deployment. By enabling low-latency, on-device computation of temporal gait parameters, the proposed solution supports continuous mobility assessment in daily-life settings and provides a foundation for future real-time feedback and intervention strategies in PD.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.