Kinematic-Encoded Spiral Drawings Enable Parkinson's Disease Detection Under Pooled Multi-Device Training
Kinematic-Encoded Spiral Drawings Enable Parkinson's Disease Detection Under Pooled Multi-Device Training
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Publication status: preprint
A plain-language reading has not been prepared for this paper yet.
Original abstract
Abstract A dual-feature kinematic renderer encodes spiral drawing velocity as a continuous colormap and pen pressure as line width, producing RGB images from raw coordinates. Per-drawing min-max normalization captures relative kinematic patterns rather than absolute sensor values, enabling pooled training across heterogeneous acquisition systems. A unified PD detection model trained on freehand spirals from an electromagnetic digitizer tablet (UCI, N = 76, Turkey) and an accelerometer-based smart pen (HandPD, N = 66, Brazil) achieves AUC 0.959 [0.921, 0.988] under memorization-safe evaluation, significantly outperforming grayscale rendering (AUC 0.850, p = 0.0008) and kinematic feature baselines (SVM: 0.757; RF: 0.867). However, leave-one-device-out transfer fails (AUC 0.443–0.542), establishing that cross-device performance requires pooled training with both device types represented. Device and site are perfectly confounded (N = 142, 50 controls); it cannot be ruled out that the model learns device-specific disease correlates. A leakage audit of published benchmarks demonstrates that augmentation-level splitting inflates AUC by 0.099.