Original abstract
Neural interfaces have advanced neuroscience and biomedical applications by aiding in the diagnosis and treatment of neurological disorders like Alzheimer's, Parkinson's, stroke, and depression. Effective neural monitoring requires electrical, chemical, and optical techniques, but challenges remain, including probe size, optical stimulation limitations, immune responses, and recording instability. Transitioning from rigid to soft materials has improved biocompatibility, flexibility, and long-term stability. Polymers like PDMS offer benefits such as transparency, flexibility, and cost-effectiveness, but their extreme softness complicates brain insertion. This Ph.D. thesis presents three major contributions focused on developing a multifunctional neural probe optimized for neuroscience applications. These innovations aim to improve precise closed-loop drug delivery using a micropump and flowmeter, enhance flexibility while preserving structural integrity for long-term stability in neural research and medical use, and advance optical functionality through nanophotonic integration. The first contribution presents a multifunctional, flexible neural probe designed for optogenetics, fluorescence excitation, drug delivery, and electrophysiological recording. The probe, measuring 0.7 mm in width, 0.1 mm in height, and 10 mm in length, integrates several key components, including a PDMS-based micropump, a precise flowmeter, a μ-LED for neural stimulation, and four microelectrodes for recording neural activity. The PDMS micropump operates via electrolysis at room temperature and features a potassium hydroxide (KOH) reservoir, a flexible membrane, a drug reservoir, and microfluidic channels, each capable of holding 20 μL of liquid. At the highest flow rate of 250 nL/min, this capacity allows for one hour of continuous drug delivery. A capacitance-based flowmeter, consisting of parallel gold-plated electrodes, measures flow rates ranging from 30 to 250 nL/min with a 5% error margin and a resolution of 20 pF per 100 pL/min. A PID controller ensures precise flow regulation by adjusting the micropump's PWM duty cycle. The second contribution offer a fully flexible, implantable neural probe made from PDMS with an adjustable-stiffness microchannel utilizing polyester. Designed for precise drug delivery, the probe features an advanced microfluidic mixer and a U- turn microchannel filled with melted polyester. Since polyester remains solid at room temperature but softens near body temperature, the probe's stiffness decreases upon tissue. The microchannel, with a cross-section of 30 μm × 30 μm and a length of 14.7 mm, was developed based on extensive simulations. The final probe dimensions, 60 μm thick, 300 μm wide, and 7 mm long, provide a buckling force exceeding 1.5 mN, sufficient for smooth insertion into brain tissue. The microfluidic mixer, measuring 90 μm × 30 μm in cross-section and 7 mm in length, demonstrated optimal drug delivery performance. Also, thermal analysis showed that the probe maintains a stable temperature of 37°C, aligning with polyester's melting point. Additionally, a 60° tip angle was determined to be optimal for insertion. The probe includes four gold electrodes (50 μm in diameter) for electrophysiological recordings and a blue μ-LED for optogenetic stimulation. Biocompatibility results demonstrated that PDMS and polyester exhibited superior performance compared to other materials, such as gallium. The third contribution presents a neural probe with eight optical switches for precise beam routing in thermogenetic applications. Using silicon-on-insulator (SOI) technology, the probe targets neurons via thermosensitive TRP channels, ensuring high spatial and temporal resolution. Each switch connects to a waveguide and grating coupler, enabling selective stimulation of multiple brain sites. The optical switching mechanism relies on the thermo-optic effect, employing an MMI splitter and a TiN heater to achieve π-phase shifting at 19.8 mW. TiN also functions as a temperature sensor, with impedance variations of 0.7 Ω for heater regulation. This thesis advances neural probe technology by enhancing drug delivery precision, flexibility, and optical functionality. By integrating soft materials, microfluidics, and optical switching, these innovations improve biocompatibility and stability, making neural interfaces more effective for neuroscience research and medical applications. Les interfaces neuronales ont permis des avancées majeures en neurosciences et en biomédecine, facilitant le diagnostic et le traitement des troubles neurologiques tels que la maladie d'Alzheimer, le Parkinson, les AVC et la dépression. Une surveillance efficace nécessite des techniques électriques, chimiques et optiques, mais des défis subsistent: taille des sondes, stimulation optique limitée, réponses immunitaires et instabilité des enregistrements. L'utilisation de matériaux souples améliore la biocompatibilité, la flexibilité et la stabilité à long terme. Les polymères comme le PDMS offrent des avantages (transparence, flexibilité, faible coût), mais leur extrême mollesse complique l'insertion cérébrale. Cette thèse propose trois contributions majeures visant à optimiser les sondes neuronales pour les neurosciences. Elles portent sur l'amélioration de l'administration de médicaments en boucle fermée, l'optimisation de la flexibilité pour une stabilité accrue et l'intégration de la nanophotonique pour une meilleure fonctionnalité optique. La première contribution concerne une sonde intégrant l'optogénétique, l'excitation par fluorescence, l'administration de médicaments et l'enregistrement électrophysiologique. De dimensions 0,7 mm × 0,1 mm × 10 mm, elle comprend une micropompe en PDMS, un débitmètre, une μ-LED pour la stimulation neuronale et quatre microélectrodes pour l'enregistrement. La micropompe fonctionne par électrolyse à température ambiante et intègre un réservoir de KOH, une membrane flexible, un réservoir de médicament et des microcanaux pouvant contenir 20 μL de liquide. À un débit maximal de 250 nL/min, elle assure une administration continue pendant une heure. Le débitmètre capacitif, composé d'électrodes plaquées or, mesure des débits de 30 à 250 nL/min avec une erreur de 5 % et une résolution de 20 pF pour 100 pL/min. Un contrôleur PID ajuste le cycle de service PWM de la micropompe pour un contrôle précis du débit. La deuxième contribution porte sur une sonde flexible en PDMS avec un microcanal en U rempli de polyester fondu, assurant une rigidité ajustable pour une meilleure insertion. Le polyester, solide à température ambiante mais ramollissant à la température corporelle, réduit la rigidité après implantation. Le microcanal (30 μm × 30 μm, 14,7 mm de longueur) est conçu sur la base de simulations approfondies. La sonde, de 60 μm d'épaisseur, 300 μm de largeur et 7 mm de longueur, génère une force de fléchissement supérieure à 1,5 mN, facilitant une insertion sans déformation. Le mélangeur microfluidique (90 μm × 30 μm, 7 mm de longueur) optimise l'administration des médicaments. L'analyse thermique montre une stabilité à 37 °C, correspondant au point de fusion du polyester. Un angle de pointe de 60° optimise l'insertion. Cette sonde inclut quatre électrodes en or (50 μm de diamètre) pour l'enregistrement électrophysiologique et une μ-DEL bleue pour la stimulation optogénétique. Les tests de biocompatibilité montrent que le PDMS et le polyester surpassent d'autres matériaux comme le gallium. La troisième contribution présente une sonde neuronale équipée de huit commutateurs optiques pour un routage précis du faisceau dans les applications thermogénétiques. Fabriquée en technologie silicium sur isolant (SOI), elle cible les neurones via des canaux TRP thermosensibles, assurant une haute résolution spatiale et temporelle. Chaque commutateur est relié à un guide d'ondes et à un coupleur de réseau, permettant une stimulation sélective de plusieurs sites cérébraux. Le mécanisme de commutation optique repose sur l'effet thermo-optique, utilisant un séparateur MMI et un élément chauffant en TiN pour induire un déphasage π à 19,8 mW. Le TiN agit aussi comme capteur de température, avec des variations d'impédance de 0,7 Ω pour réguler le chauffage, garantissant une stimulation neuronale contrôlée. Cette thèse fait progresser la technologie des sondes neuronales en améliorant la précision de l'administration des médicaments, la flexibilité et la fonctionnalité optique. En intégrant des matériaux souples, la microfluidique et la commutation optique, ces innovations augmentent la biocompatibilité et la stabilité, rendant les interfaces neuronales plus efficaces pour la recherche en neurosciences et les applications médicales.