In vivo vesicular acetylcholine transporter density in human peripheral organs: an [18F]FEOBV PET/CT study.
In vivo vesicular acetylcholine transporter density in human peripheral organs: an [18F]FEOBV PET/CT study.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
DK · Author affiliation · country only
Department of Nuclear Medicine and PET, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, J220, 8200, Aarhus N, Denmark. jacobnls@rm.dk.Location evidence
Newcastle upon Tyne, GB · Author affiliation
Institute of Translational and Clinical Research, University of Newcastle Upon Tyne, Newcastle upon Tyne, UK.Location evidence
Follow the study behind this paper
Imaging the Vesicular Acetylcholine Transporter Using 18F-FEOBV PET in Parkinsons Disease
The registry links this paper to the study.
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: The autonomic nervous system is frequently affected in some neurodegenerative diseases, including Parkinson's disease and Dementia with Lewy bodies. In vivo imaging methods to visualize and quantify the peripheral cholinergic nervous system are lacking. By using [18F]FEOBV PET, we here describe the peripheral distribution of the specific cholinergic marker, vesicular acetylcholine transporters (VAChT), in human subjects. We included 15 healthy subjects aged 53-86 years for 70 min dynamic PET protocol of peripheral organs. We performed kinetic modelling of the adrenal gland, pancreas, myocardium, renal cortex, spleen, colon, and muscle using an image-derived input function from the aorta. A metabolite correction model was generated from venous blood samples. Three non-linear compartment models were tested. Additional time-activity curves from 6 to 70 min post injection were generated for prostate, thyroid, submandibular-, parotid-, and lacrimal glands. RESULTS: A one-tissue compartment model generated the most robust fits to the data. Total volume-of-distribution rank order was: adrenal gland > pancreas > myocardium > spleen > renal cortex > muscle > colon. We found significant linear correlations between total volumes-of-distribution and standard uptake values in most organs. CONCLUSION: High [18F]FEOBV PET signal was found in structures with known cholinergic activity. We conclude that [18F]FEOBV PET is a valid tool for estimating VAChT density in human peripheral organs. Simple static images may replace kinetic modeling in some organs and significantly shorten scan duration. Clinical Trial Registration Trial registration: NCT, NCT03554551. Registered 31 May 2018. https://clinicaltrials.gov/ct2/show/NCT03554551?term=NCT03554551&draw=2&rank=1 .