Examination of simple artificial intelligence-based analysis of dopamine transporter scintigraphy for supporting a diagnosis of Parkinson’s disease

Examination of simple artificial intelligence-based analysis of dopamine transporter scintigraphy for supporting a diagnosis of Parkinson’s disease

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Explore research worldwide

Publication status: preprint

A plain-language reading has not been prepared for this paper yet.

Original abstract

Abstract Introduction: In the Movement Disorder Society criteria for the diagnosis of Parkinson's disease (PD), evaluation of the presynaptic dopamine system should be performed using dopamine transporter single-photon emission computed tomography (DAT SPECT). However, it is difficult for unexperienced physicians to detect a mild defect. Here, we attempted to develop a simple deep learning-based image analysis method to evaluate DAT SPECT images. Methods We used data from 300 patients who were diagnosed with PD and 102 control patients with non-neurodegenerative diseases as the artificial intelligence (AI) development cohort. For validation, we analyzed the data of 96 patients with PD from an independent cohort. We divided the development cohort into the training and test sets. Using the training set, we performed transfer learning using six pre-trained convolutional neural network architectures, and created AI models. We evaluated their accuracy, sensitivity, and area under the receiver operating characteristic curve, and further confirmed their validity by using the validation cohort. In addition, we compared the accuracy of the best AI model with that of two experienced neurologists and a resident. Results The selected AI model could interpret DAT SPECT images with an accuracy of 0.959; accuracy in the validation cohort was 0.8959–1. There was no significant difference between the accuracy of the AI model and physicians. Conclusion Our simple AI model for the interpretation of DAT SPECT images was accurate and robust. Its accuracy was equivalent to that of physicians.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE