Automated eye-tracking for Parkinson's disease diagnosis: a proof-of-concept cascade classifier study.
Automated eye-tracking for Parkinson's disease diagnosis: a proof-of-concept cascade classifier study.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Tucson, US · Author affiliation
University of Arizona, Tucson, AZ 85721, USA.Location evidence
Phoenix, US · Author affiliation
Barrow Neurological Institute, 240 West Thomas Road, Suite 301, Phoenix, AZ 85013, USA.Location evidence
Hopkins, US · Author affiliation
Johns Hopkins University, 3400 North Charles Street, Baltimore, MD 21218, USA.Location evidence
Baltimore, US · Author affiliation
Johns Hopkins University, 3400 North Charles Street, Baltimore, MD 21218, USA.Location evidence
US · Author affiliation · country only
Consultant, Cleveland, OH, USA.Location evidence
Follow the study behind this paper
Complex Eye Movements in Parkinson's Disease and Related Movement Disorders
The registry links this paper to the study.
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: Parkinson's disease (PD) is a progressive neurodegenerative disorder of increasing prevalence, with diagnostic accuracy of approximately 26% in early symptomatic patients. There is a need for accurate, non-invasive biomarkers to aid in disease diagnosis. METHODS: This proof-of-concept study enrolled 90 participants (PD n = 30, other movement disorders [OM] n = 30, healthy controls [HC] n = 30) at a single institution. Participants completed two 10-min eye- tracking sessions using the SaccadeDX™ 250-Hz binocular system. A two-level cascade classifier was fitted using elastic-net feature selection followed by logistic regression on the selected features, validated by 10-fold cross-validation. The cascade distinguished HC from movement disorders (Level 1) and PD from OM (Level 2), with the objective of establishing clinical validity - that an eye-tracking signal correlates reliably with PD diagnosis. RESULTS: Level 1 achieved an area under the curve (AUC) of 0.818 (95% CI: 0.71, 0.91), with a sensitivity of 83% and specificity of 63%. Level 2 achieved an AUC of 0.670 (95% CI: 0.52, 0.80), with a sensitivity of 68% and specificity of 63%. As a proof-of-concept study, the observed performance positions the device as an adjunctive screening tool. Diagnostic discrimination can only be achieved through a much larger Phase III study. Five adverse events were recorded (three cases of dizziness, one of nausea, and one of dry eyes); one participant withdrew from the study. CONCLUSIONS: Preliminary evidence supports clinical validity pending confirmatory Phase III study: reproducible eye-tracking signal for PD is detectable using a two-level cascade classifier. A multi-center confirmatory study is warranted before assessment of clinical utility.Trial registration. ClinicalTrials.govNCT04925622.