Closed-loop deep brain stimulation (cDBS) for Parkinson’s disease requires control strategies that tolerate noisy sensing, patient-specific stimulation responses, medication-related fluctuations, and embedded hardware constraints. We developed a patient-calibrated minute-scale dynamical model of subthalamic beta activity and an embedded explicit trend–zone predictive controller, eTZPC. The model combined a basal-ganglia mechanistic prior with stimulation-amplitude and medication-cycle recordings from five patients, and incorporated individualized stimulation- β STN maps, fast- and slow-timescale stimulation responses, levodopa-related modulation, background drift, and observation noise. eTZPC was designed to maintain β STN activity within a patient-specific target zone under stimulation-amplitude, step-size, and quantization constraints. Compared with dual-threshold (DT) and proportional–integral–derivative (PID) controllers across four disturbance scenarios, eTZPC achieved target-zone regulation close to PID while reducing stimulation-switching burden toward the low-switching profile of DT. Ablation analyses identified distinct contributions of smoothing, trend prediction, patient-specific action modeling, and embedded explicit implementation. Parameter-mismatch tests showed that eTZPC was relatively robust to dynamic and disturbance-parameter deviations, but remained sensitive to errors in the steady-state stimulation– β STN map. Patient-in-the-loop recordings in five patients further confirmed execution consistency and compliance with stimulation-boundary and step-size constraints. These findings support patient-calibrated dynamical modeling combined with low-complexity explicit control as a feasible framework for further embedded cDBS evaluation.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE