RESEARCH / DISCOVERY
← Back to the library

Objective Assessment of Impulse Control Disorder in Patients with Parkinson’s Disease Using a Low-Cost LEGO-Like EEG Headset

Objective Assessment of Impulse Control Disorder in Patients with Parkinson’s Disease Using a Low-Cost LEGO-Like EEG Headset

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Explore research worldwide

Publication status: preprint

A plain-language reading has not been prepared for this paper yet.

Original abstract

Background: Patients with Parkinson’s disease (PD) can develop the cognitive adverse effect of impulse control disorders (ICDs) while undergoing a pharmacological treatment for motor control dysfunctions with a dopamine agonist (DA). Conventional clinical interviews or questionnaires can be biased and may not provide an accurate diagnosis in the early stage. A wearable electroencephalogram (EEG)-sensing headset paired with an examination procedure can be a potential user-friendly method to explore ICD-related biomarkers that can reflect brain activity abnormalities and detect its early signs and progression.MethodsA stereotypical Go/NoGo test that targets impulse inhibition was performed with 59 individuals, including heathy controls, patients with PD, and patients with PD diagnosed with ICD. A low-cost LEGO-like EEG headset was used to record concurrent EEG signals. The event-related potential (ERP) analytical framework was then used to explore ICD-related EEG abnormalities after DA treatment.ResultsOnly PD patients with ICD exhibited a tendency for N2 and P3 amplitude deterioration at the fronto-central regions (i.e., Fz, FCz, and Cz); in particular, the P3 counterpart reached statistical significance (p<0.05). Neither PD patients nor healthy controls (without DA) replicated such findings. Furthermore, N2 amplitude deterioration was found to be related to ICD severity at Fz (r=-0.28, p=0.04).ConclusionsA low-cost LEGO-like EEG headset successfully captured ERP neuromarkers for the objective assessment of ICD in PD patients undergoing DA treatment. The present objective neuro-evidence could provide complementary information to conventional clinical scales used to diagnose the ICD adverse effect.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE