CheckPD App Smartphone Motor Time-Series Modeling for Parkinson Disease Case-Control Discrimination: Internal Validation Study.
CheckPD App Smartphone Motor Time-Series Modeling for Parkinson Disease Case-Control Discrimination: Internal Validation Study.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Bangkok, TH · Author affiliation
Chulalongkorn Centre of Excellence for Parkinson's Disease & Related Disorders, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 1873 Rama 4 Road, Bangkok, 10330, Thailand, 66 22564000.Location evidence
Pathum Thani, TH · Author affiliation
National Electronics and Computer Technology Centre, National Science and Technology Development Agency, Pathum Thani, Thailand.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: Smartphone inertial measurement unit (IMU) and touchscreen tasks can capture Parkinson disease (PD)-related motor information, but deep-learning analyses require participant-level leakage control and cautious clinical interpretation. OBJECTIVE: This study aimed to compare bidirectional long short-term memory (BiLSTM) and one-dimensional convolutional BiLSTM (Conv1D-BiLSTM) models applied to CheckPD smartphone motor-task time series and evaluate whether stacked ensembles improve internal case-control discrimination. METHODS: We performed a retrospective case-control modeling analysis of 679 participants: 344 with neurologist-confirmed PD and 335 neurologist-confirmed healthy controls. Five tasks were analyzed: Rest Tremor, Postural Tremor, Balance, GaitWalk, and PinchToSize. Participant-level splitting preceded windowing or touchscreen-session construction. Models were developed using stratified 5-fold cross-validation, with out-of-fold predictions used for ensemble training. Five-fold-trained task-specific models were evaluated separately on the same internal held-out complete-case cohort of 90 participants (45 PD and 45 healthy controls), and individual-task performance metrics were averaged across models. Ensembles were evaluated at the participant level. RESULTS: Conv1D-BiLSTM achieved a higher receiver operating characteristic area under the curve (ROC-AUC) than BiLSTM for Rest Tremor (0.8854 vs 0.8087), Postural Tremor (0.8750 vs 0.6813), Balance (0.8627 vs 0.6675), and GaitWalk (0.8700 vs 0.7090). PinchToSize showed a slightly higher ROC-AUC with BiLSTM (0.8410 vs 0.8340). The Conv1D-BiLSTM Main Symptoms ensemble (Rest Tremor, GaitWalk, and PinchToSize) achieved the highest observed ROC-AUC (0.9131, 95% CI 0.8439-0.9695) and precision-recall area under the curve (0.9354, 95% CI 0.8901-0.9822). The Conv1D-BiLSTM Easy ensemble (Rest Tremor, Postural Tremor, and Balance) achieved the highest macro-F 1-score (0.8534) and accuracy (77/90, 86%) at the evaluation classification rule. CONCLUSIONS: Deep sequence modeling of CheckPD smartphone motor-task time series showed promising internal case-control discrimination. The findings support further evaluation of multidomain smartphone motor assessment as a potential adjunct to prespecialist clinical assessment. They do not establish diagnostic validity, calibrated clinical risk prediction, or readiness for clinical use. Prospective external validation, differential diagnosis testing, calibration, and workflow evaluation are required.