RESEARCH / DISCOVERY
← Back to the library

Linker-free immobilization of choline oxidase on synergistic Au-Pt/MXene hybrid interface for enhanced electrochemical choline detection.

Linker-free immobilization of choline oxidase on synergistic Au-Pt/MXene hybrid interface for enhanced electrochemical choline detection.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Seoul, KR · Author affiliation

Brain Science Institute, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea; Division of Bio-Medical Science & Technology, KIST School, University of Science & Technology (UST), Seoul, 02792, Republic of Korea.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Neurological disorders such as Parkinson's and Alzheimer's diseases are closely linked to neurotransmitter dysregulation, highlighting the urgent need for sensitive and selective electrochemical diagnostic platforms. Conventional biosensors relying solely on natural enzymes or nanomaterial catalysts are limited by poor operational stability and insufficient substrate selectivity. Integrating both components offers a promising route to overcome these constraints. We report a synergistic enzyme-nanocomposite biosensing platform built on co-electrodeposition of AuPt nanoclusters with subsequent 2D MXene assembly on a patterned electrode, enabling linker-free immobilization of choline oxidase (ChOx). This approach affords precise control over film morphology and interfacial properties, while the conductive Au-Pt/MXene scaffold provides abundant functional groups for stable enzyme anchoring without external cross-linkers. The resulting Au-Pt/MXene/ChOx/NF architecture achieves a wide linear detection range (0.001-1000 μM), high sensitivity (238.2 μA mM-1 cm-2), and a low detection limit of 0.1 μM for choline. The biosensor retained >90% of its initial response after 15 days and exhibited high selectivity toward common interferents, including dopamine, serotonin, lactate, and glucose (1 μM each). In artificial cerebrospinal fluid (ACSF), recoveries of 97.6-102.8% with RSDs below 1.54% demonstrated the high precision and robust analytical performance of the biosensor for choline determination. This scalable platform demonstrates strong potential for point-of-care neurotransmitter monitoring and next-generation electrochemical biosensing applications.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE