RESEARCH / DISCOVERY
← Back to the library

Association of subthalamic deep brain stimulation programming parameters with cognitive trajectories in Parkinson's disease.

Association of subthalamic deep brain stimulation programming parameters with cognitive trajectories in Parkinson's disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Homburg, DE · Author affiliation

Department of Neurology, Saarland University, Homburg, Germany; Neuroimaging Center, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Location evidence

Mainz, DE · Author affiliation

Department of Neurology, Saarland University, Homburg, Germany; Neuroimaging Center, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Location evidence

Madrid, ES · Author affiliation

Department of Neurosurgery and Neurology, University Hospital La Princesa, Madrid, Spain.
Location evidence

Heidelberg, DE · Author affiliation

Department of Neurology, University Hospital Heidelberg, Heidelberg, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

High-frequency deep brain stimulation (DBS) targeting the subthalamic nucleus (STN) is an effective therapy for motor symptoms in Parkinson's disease (PD). However, its impact on cognition remains debated. This retrospective, observational study of 78 consecutive PD patients who underwent bilateral STN-DBS aimed to investigate the association between STN-DBS parameter settings (pulse width, amplitude, and frequency) and cognitive outcomes over twelve months in PD, as well as their link to motor functioning. Among the evaluated DBS programming parameters, pulse width emerged as the only factor consistently associated with longitudinal cognitive trajectories. This association remained robust across multiple sensitivity analyses, including patient-level and motor-adjusted models, whereas amplitude and frequency showed no significant relationships with cognition. Patients with pulse widths <60 μs showed a greater likelihood of cognitive decline compared to those with standard (60 μs) or longer widths. Our results suggest that pulse width may represent an underrecognized determinant of cognitive outcomes following STN-DBS and support its consideration in future prospective studies aimed at optimizing DBS programming beyond motor symptoms alone.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE