RESEARCH / DISCOVERY
← Back to the library

Responder Analysis of the Therapeutic Effect of Magnetic Resonance-Guided Focused Ultrasound Thalamotomy on Essential Tremor Correlates with Functional Improvement.

Responder Analysis of the Therapeutic Effect of Magnetic Resonance-Guided Focused Ultrasound Thalamotomy on Essential Tremor Correlates with Functional Improvement.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Kiel, DE · Author affiliation

Department of Neurology, University Hospital Schleswig-Holstein, Christian-Albrechts-University, Kiel, Germany.
Location evidence

Centro, ES · Author affiliation

Centro Integral de Neurociencias AC (CINAC), HM Universitario Puerta del Sur, Madrid, Spain.
Location evidence

Madrid, ES · Author affiliation

Centro Integral de Neurociencias AC (CINAC), HM Universitario Puerta del Sur, Madrid, Spain.
Location evidence

Universidad, ES · Author affiliation

Universidad CEU-San Pablo, Madrid, Spain.
Location evidence

Barcelona, ES · Author affiliation

Department of Neurology, Hospital de la Santa Creu y Sant Pau, Barcelona, Spain.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Outcomes of focused ultrasound thalamotomy (ventral intermediate nucleus focused ultrasound [Vim-FUS]) for essential tremor are usually reported as group-level tremor reductions, which may not reflect individual improvements in activities of daily living (ADL). OBJECTIVE: The aim was to identify tremor amplitude thresholds defining functionally relevant individual response. METHODS: Eighty-four patients were assessed at baseline and 3 months after Vim-FUS using blinded video ratings of hand tremor amplitude (rest, postural, wing beating, intention) and the Essential Tremor Rating Assessment Scale. Linear mixed-effects models examined associations between tremor components and ADL impairment. Nonlinear modeling identified ADL-relevant amplitude thresholds. RESULTS: Treated-side intention tremor was the only component independently associated with residual ADL impairment. Categories based on this amplitude comprised full response (<0.5 cm, n = 42), partial response (0.5-<2 cm, n = 39), and nonresponse (≥2 cm, n = 3). CONCLUSIONS: Intention tremor amplitude is a key indicator of functional outcome after Vim-FUS. These thresholds provide clinically meaningful criteria for individual response classification, warranting further validation. © 2026 The Author(s). Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.