RESEARCH / DISCOVERY
← Back to the library

Oculomotor and Pupillary Biomarkers for Detecting and Staging Parkinson's Disease.

Oculomotor and Pupillary Biomarkers for Detecting and Staging Parkinson's Disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Explore research worldwide

Publication status: preprint

A plain-language reading has not been prepared for this paper yet.

Original abstract

Purpose To evaluate to what degree multimodal oculomotor, vestibular, reaction time, and cognitive (OVRT-C) metrics differentiate Parkinson's disease (PD) from healthy aging and to determine their association with clinical severity. Methods This is a cross-sectional diagnostic-accuracy study, 42 participants with established PD and 24 healthy controls completed a 23-test OVRT-C battery using portable video-oculography between 2023 and 2024. Group differences, age and sex-adjusted logistic regression, and cross-sectional associations with Hoehn and Yahr severity were examined. A parsimonious multivariable model was evaluated with leave-one-out cross-validation (LOOCV). Results PD was characterized by reduced saccadic accuracy, greater hypometria, impaired smooth pursuit and vergence, increased fixation-instability/nystagmus measures, and altered pupillary responses. The final multiple regression model combined vertical saccadic accuracy, horizontal and vertical gaze nystagmus counts in darkness, and predictive-saccade accuracy (AUC 0.975, 95% CI 0.917-0.995; sensitivity 0.950; specificity 0.870). Performance decreased with LOOCV (AUC 0.940, 95% CI 0.850-0.980; sensitivity 0.875; specificity 0.826). Horizontal saccade latency, vertical smooth-pursuit gain, and pupillary measures were associated with greater cross-sectional Hoehn and Yahr severity. Conclusions OVRT-C-derived oculomotor and pupillometric metrics discriminated participants with established PD from healthy controls, whereas vestibular measures contributed little to diagnostic classification. These findings support prospective validation of OVRT-C metrics as candidate biomarkers for PD and for cross-sectional disease characterization but will require rigorous validation.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE