RESEARCH / DISCOVERY
← Back to the library

EEG-based deep learning reveals cortical sensitivity to small changes in deep brain stimulation parameters.

EEG-based deep learning reveals cortical sensitivity to small changes in deep brain stimulation parameters.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

London, GB · Author affiliation

Care Research and Technology Centre, UK Dementia Research Institute, London, United Kingdom; Department of Computing, Imperial College London, London, United Kingdom; UKRI Centre for Doctoral Training in AI for Healthcare, Imperial College London, London, UK.
Location evidence

Guildford, GB · Author affiliation

Care Research and Technology Centre, UK Dementia Research Institute, London, United Kingdom; Department of Brain Sciences, Imperial College London, London, United Kingdom; School of Psychology, University of Surrey, Guildford, United Kingdom. Electronic address: s.haar@imperial.ac.uk.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Deep Brain Stimulation (DBS) is an invasive procedure used to alleviate motor symptoms in Parkinson's Disease (PD) patients. Despite its effectiveness, the impact of DBS on brain activity and the way to optimise stimulation parameters remains unclear. In this study, we aimed to map the sensitivity of cortical neural response to changes in DBS parameters in real-world clinical settings. We recorded in-clinic EEG data from PD patients during their clinical DBS programming sessions, both at rest and during arm movement. A siamese variant of the EEGNet deep learning architecture was trained independently for each patient and parameter combination to determine whether two 1-sec-long EEG segments were recorded under the same or different DBS parameters, yielding 30 independently trained models. Our models achieved an average accuracy of 74% in classifying whether two 1-second EEG segments corresponded to the same or different DBS parameters. Explainability methods were then applied to extract the neural oscillations learned by the models. Ablation studies identified mid-gamma oscillations (55-90 Hz) as the key band for classifying these changes. Importantly, that was not driven by 1:2 gamma entrainment. In a sub-group of patients, the theta-alpha oscillations (4-12 Hz) also contributed to detecting changes in DBS parameters. We demonstrate that small DBS parameter changes modify cortical activity in a consistent manner that can be detected using shallow convolutional networks on low-density EEG. Our findings suggest that cortical mid-gamma oscillations (55-90 Hz) are highly sensitive to small changes in DBS settings. Our approach and findings could be leveraged towards identifying and defining novel digital biomarkers to guide DBS programming and adaptive DBS systems.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE