RESEARCH / DISCOVERY
← Back to the library

AS-ULDAR: a ROS 2-based collaborative robotic platform for upper-limb rehabilitation - systems integration and pilot usability evaluation in a clinical environment.

AS-ULDAR: a ROS 2-based collaborative robotic platform for upper-limb rehabilitation - systems integration and pilot usability evaluation in a clinical environment.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Pavia, IT · Author affiliation

Department of Computer, Electrical, and Biomedical Engineering, University of Pavia, Pavia, Italy.
Location evidence

IT · Author affiliation · country only

Neurophysiopathology Unit, Montescano Institute, Istituti Clinici Scientifici Maugeri IRCCS, Montescano, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Robotic rehabilitation can increase the intensity and personalization of upper-limb therapy, but its clinical translation is hindered by the difficulty of integrating individually validated technical components into a single clinician-ready platform. This paper presents a platform which is intended to be an Auto-calibrating System for Upper Limb Disability Assessment and Rehabilitation (AS-ULDAR), a ROS 2-based platform built around a Franka Emika Panda robot that unifies motor/cognitive assessment, sensorless force estimation, and Cartesian and Human Joint-based Trajectory Tracking within a clinician-oriented GUI. While these functionalities were individually validated in prior work, the present contribution lies in their systems-level integration and in identifying the operational barriers that emerge when deploying such a platform in a real clinical workflow, targeting adult patients with chronic neurological conditions (stroke, Parkinson's, ALS, MCI) and mild-to-moderate upper-limb impairment. The platform was evaluated through a formative usability study: the standalone GUI by five naïve users, and the complete system by seven physiotherapists performing the full clinical workflow (no patients were involved; clinical efficacy is outside this scope). The system was technically stable throughout. Usability (SUS) was high for the GUI (87.5 ± 1.8) but markedly lower and more heterogeneous for the complete platform (54 ± 16), with feedback pointing to robot setup and workflow operation-not interface design-as the main friction points for clinical staff. These results show that integrating multiple rehabilitation functionalities is technically feasible, but that usability must be treated as a system-level property, and they provide concrete operational lessons for the clinical translation of cobot-based rehabilitation platforms.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE