No Additional Benefit of 185 Hz Versus 130 Hz at Equivalent Energy in Deep Brain Stimulation for Tremor: A Randomized Prospective Clinical Trial.
No Additional Benefit of 185 Hz Versus 130 Hz at Equivalent Energy in Deep Brain Stimulation for Tremor: A Randomized Prospective Clinical Trial.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
DE · Author affiliation · country only
Department of Neurology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.Location evidence
Berlin, DE · Author affiliation
Department of Neurology with Experimental Neurology, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany.Location evidence
Jülich, DE · Author affiliation
Cognitive Neuroscience, Institute of Neuroscience and Medicine (INM3)-Research Center Jülich, Jülich, Germany.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: Deep brain stimulation (DBS) of the ventral intermediate nucleus and posterior subthalamic area (VIM/PSA) in Essential Tremor (ET) and the subthalamic nucleus (STN) in Parkinson's disease (PD) are established treatments for tremor. To achieve maximum tremor control, increasing stimulation frequency beyond 130 Hz is part of clinical practice, but lacks scientific evidence. OBJECTIVE: To compare tremor suppression under total electrical energy delivered (TEED)-equivalent stimulation at 130 versus 185 Hz in VIM/PSA-DBS for ET and STN-DBS for PD. METHODS: In this prospective, double-blind study, acute DBS effects were assessed in 18 people with ET (n = 29 hemispheres), and 25 people with PD (n = 30 hemispheres). Tremor-suppressive effects, evaluated by accelerometry, were compared with TEED-equivalent stimulation at 130 and 185 Hz using linear mixed-effects models, explorative pairwise comparisons, and equivalency testing. RESULTS: Linear mixed-effects models revealed no significant effect of stimulation frequency on tremor improvement in both cohorts. Pairwise comparisons showed no consistent differences in total tremor improvement with TEED-equivalent 130 Hz vs 185 Hz DBS. Post-hoc equivalence testing confirmed equivalence of stimulation frequencies under TEED-equivalent conditions within a ±20% margin of relative tremor improvement. CONCLUSION: This study provides Level II evidence that a higher stimulation frequency of 185 Hz does not offer additional benefit in deep brain stimulation for tremor in VIM/PSA for Essential Tremor or in the STN for Parkinson's Disease in the acute setting and supports 130 Hz as the standard stimulation frequency for tremor suppression.