RESEARCH / DISCOVERY
← Back to the library

Accuracy of Machine Learning in Differential Diagnosis of Multiple System Atrophy: A Systematic Review and Meta-Analysis.

Accuracy of Machine Learning in Differential Diagnosis of Multiple System Atrophy: A Systematic Review and Meta-Analysis.

Read the original publication

Where did the research take place?

Possible study sites were matched from the text; these need review.

Cochrane, CA · Possible study site

METHODS: We conducted a systematic search in PubMed, Embase, Cochrane Library, and Web of Science (up to July 5, 2025), including ML-based MSA diagnostic studies.
Location evidence

Yinchuan, CN · Author affiliation

School of Clinical Medicine, Ningxia Medical University, Yinchuan, China.
Location evidence

Nanchang, CN · Author affiliation

School of Clinical Medicine, Nanchang University, Nanchang, China.
Location evidence

Chengdu, CN · Author affiliation

School of Clinical Medicine, Sichuan University, Chengdu, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Multiple system atrophy (MSA) is frequently misdiagnosed as Parkinson's disease (PD) or progressive supranuclear palsy (PSP), posing significant diagnostic challenges. OBJECTIVE: The aim of the study was to systematically evaluate the efficacy of machine learning (ML) in differentiating MSA from other neurodegenerative disorders. METHODS: We conducted a systematic search in PubMed, Embase, Cochrane Library, and Web of Science (up to July 5, 2025), including ML-based MSA diagnostic studies. QUADAS-2 assessed bias risk, and a bivariate mixed-effects model synthesized diagnostic metrics. RESULTS: A total of 51 studies (comprising 3595 MSA patients and 18,189 total cases) were included in the systematic review. Of these, 38 studies contributed to the quantitative synthesis, whereas the remaining 13 studies were summarized qualitatively. In the primary analysis comparing MSA with PD, the pooled sensitivity was 0.86 (95% confidence interval [CI]: 0.81-0.90), specificity 0.87 (95% CI: 0.83-0.90), and the area under the summary receiver operating characteristic (SROC) curve (AUC) 0.93 (95% CI: 0.90-0.95). Overall, pooled sensitivity was 0.85 (95% CI: 0.82-0.88), specificity 0.92 (95% CI: 0.89-0.94), and AUC 0.94 (95% CI: 0.92-0.96). Positron emission tomography (PET)-based models achieved optimal performance (sensitivity: 0.90, specificity: 0.96, AUC: 0.97), whereas deep learning models outperformed others (sensitivity: 0.93, specificity: 0.98, AUC: 0.99). CONCLUSION: ML models integrating PET/magnetic resonance imaging (MRI) data demonstrate high diagnostic accuracy for MSA. Future work should prioritize prospective multicenter validation and standardized external testing to facilitate clinical implementation.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE