RESEARCH / DISCOVERY
← Back to the library

Deep Learning-Based Parkinson's Disease Classification Using RGB Plantar Pressure Gait Images: A Comparative Study of CNN and Transformer Architectures.

Deep Learning-Based Parkinson's Disease Classification Using RGB Plantar Pressure Gait Images: A Comparative Study of CNN and Transformer Architectures.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Taichung, TW · Author affiliation

Department of Life Sciences, College of Life Sciences, National Chung-Hsing University, Taichung 402, Taiwan.
Location evidence

Changhua, TW · Author affiliation

Adult Respiratory Therapy Division, Changhua Christian Hospital, Changhua 500, Taiwan.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Background/Objectives: Parkinson's disease (PD) is associated with gait abnormalities that provide quantitative information on motor function. This study developed and evaluated a signal-to-image deep learning framework for distinguishing participants with diagnosed PD from healthy controls using plantar pressure gait signals. Methods: VGRF signals from the PhysioNet Gait in Parkinson's Disease Database were transformed into RGB images encoding left-foot pressure, right-foot pressure, and the absolute bilateral difference. ResNet50, EfficientNet-B0, ViT-Tiny, and Swin-Tiny were evaluated at three resolutions and compared with 1D-CNN and BiLSTM baselines. Repeated subject-level five-fold cross-validation with three repetitions and participant-level bootstrap analysis were performed. Results: Among RGB models, ViT-Tiny at 384 × 384 achieved a mean accuracy of 77.64%, F1-score of 82.82%, and AUC of 86.40%. In the Swin-Tiny 384 × 384 ablation, the absolute bilateral-difference representation achieved the highest mean AUC (86.68%). However, its participant-level AUC advantage over RGB was not statistically conclusive (ΔAUC = 0.030, 95% CI: -0.011 to 0.068). Conclusions: Signal-derived gait images provide a feasible approach for PD classification, with bilateral-difference information showing potential discriminative value.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE