RESEARCH / DISCOVERY
← Back to the library

Reject Option for Medical Image Classification Using CNN-Derived Latent-Space Neighbourhood Analysis.

Reject Option for Medical Image Classification Using CNN-Derived Latent-Space Neighbourhood Analysis.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Pisa, IT · Author affiliation

Bioengineering Unit, Fondazione Toscana G. Monasterio, Via Giuseppe Moruzzi, 1, Pisa, 56124, Italy.
Location evidence

Massa, IT · Author affiliation

Bioengineering Unit, Fondazione Toscana G. Monasterio, via Aurelia Sud 309, Massa, 54100, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Reliable uncertainty estimation is a key requirement for the clinical adoption of convolutional neural networks (CNNs) in biomedical imaging. We propose a reject option framework that assesses prediction reliability by leveraging the local structure of the latent space. The method is based on three latent-space features: Simple Data Point Target Density ( DPTD S ), defined as the proportion of a sample's nearest neighbours sharing its label, a distance-weighted extension ( DPTD W ), and the k ∗ value. These metrics characterise local label agreement and intra-class consistency without relying on explicit parametric assumptions. A logistic regression rejector is trained post hoc using features derived from the latent representations of the base CNN. Experiments were conducted on two public neuroimaging datasets: ADNI (FDG-PET for Alzheimer's disease) and PPMI (DaTSCAN SPECT for Parkinson's disease). Using all three latent-space features, the rejector achieved AUC-ROC values of 0.843 (95% CI: 0.809-0.874) on ADNI and 0.884 (95% CI: 0.867-0.900) on PPMI, with corresponding eAURC values of 0.0278 (95% CI: 0.0193-0.0370) and 0.0169 (95% CI: 0.0133-0.0209), respectively. For the full-feature configuration, no significant difference from maximum softmax probability (MSP) was detected on ADNI for either AUC-ROC or eAURC, whereas MSP performed significantly better on PPMI for both metrics. The proposed framework provides a representation-based mechanism to assess prediction reliability through local latent-space structure. As a post-hoc approach, it can be integrated into existing CNN pipelines without modifying the underlying model, offering a practical tool for uncertainty-aware decision support in biomedical imaging.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE