RESEARCH / DISCOVERY
← Back to the library

Feasibility Study of Deep Learning-Driven Image Restoration for Fast, Low-Count [18F]FP-CIT Digital PET/CT.

Feasibility Study of Deep Learning-Driven Image Restoration for Fast, Low-Count [18F]FP-CIT Digital PET/CT.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Seoul, KR · Author affiliation

Department of Nuclear Medicine, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, 150, Seongan-ro, Gangdong-gu, Seoul 05355, Republic of Korea.
Location evidence

Uijeongbu-si, KR · Author affiliation

Department of Neurology, Uijeongbu Eulji Medical Center, Eulji University School of Medicine, 712, Dongil-ro, Uijeongbu-si 11759, Republic of Korea.
Location evidence

Seongnam-si, KR · Author affiliation

Department of Radiological Science, College of Health Science, Eulji University, 553, Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Republic of Korea.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Background/Objectives: N-3-[18F]fluoropropyl-2β-carbomethoxy-3β-4-iodophenyl nortropane ([18F]FP-CIT) positron emission tomography/computed tomography (PET/CT) is an effective imaging tool for diagnosing parkinsonism. This study evaluated the feasibility of deep learning (DL)-driven image restoration of short-duration [18F]FP-CIT images. Methods: List-mode data from 202 patients who underwent [18F]FP-CIT PET/CT were reconstructed into 30-s (30sec), 1-min (1min), and reference 10-min (10min) acquisition durations. Patients were divided into training, validation, and test sets in a 6:2:2 ratio. The U-Net model was implemented to generate the DL images from 30sec and 1min data. The visual image quality was assessed using a three-point scale, visual interpretation of striatal dopamine transporter binding patterns, regional standardized uptake value ratios (SUVRs), and quantitative quality metrics including the peak signal-to-noise ratio, root mean squared error, and universal quality index among five series of images: 30sec, 1min, DL-30sec, DL-1min, and 10min. Results: While 30sec and 1min low-count scans showed poor image quality, the DL-driven algorithm showed significant improvement; DL-1min scans achieved excellent ratings in 95% of cases. Concordance with the reference images was 85.0% for visual image quality and 92.5% for visual interpretation in the DL-30sec images, and 97.5% and 92.5%, respectively, in the DL-1min images. Discordant interpretations occurred mainly in patients with atypical parkinsonism. Regional SUVR values and quantitative metrics for the DL-1min images showed good agreement and smaller biases with respect to the reference images, compared with those of DL-30sec images. Conclusions: The DL-driven method generated clinically acceptable [18F]FP-CIT images while reducing acquisition time, with better image quality in the DL-1min than in the DL-30sec images. Concordance in visual interpretation was reduced in the small subgroup of patients with atypical parkinsonism.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE