RESEARCH / DISCOVERY
← Back to the library

Impact of a Novel Pre-Procedural ECG Schematic for Accessory Pathway Localization on Procedural Outcomes of Radiofrequency Catheter Ablation in Typical Wolff-Parkinson-White Syndrome.

Impact of a Novel Pre-Procedural ECG Schematic for Accessory Pathway Localization on Procedural Outcomes of Radiofrequency Catheter Ablation in Typical Wolff-Parkinson-White Syndrome.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Hanoi, VN · Author affiliation

Health Management Training Institute, Hanoi University of Public Health (HUPH), Vietnam
Location evidence

VN · Author affiliation · country only

Department of Internal Medicine, Vietnam University of Traditional Medicine (VUTM), Vietnam
Location evidence

Bạch Mai, VN · Author affiliation

Vietnam National Heart Institute, Bach Mai Hospital, Hanoi, Vietnam.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND/AIMS: This study aimed to evaluate the clinical efficacy, procedural metrics, and safety outcomes of radiofrequency catheter ablation (RFCA) for typical Wolff - Parkinson - White (WPW) syndrome utilizing a pre-procedural 12-lead surface electrocardiogram (ECG) schematic for accessory pathway (AP) localization in a Vietnamese cohort. METHODS: A prospective, descriptive study was performed on 109 consecutive patients with typical WPW syndrome undergoing electrophysiological study (EPS) and RFCA. A stepwise 12-lead ECG algorithm (the new schematic) was applied to predict the AP anatomical site prior to ablation, which was validated against intraprocedural electroanatomical mapping endpoints. Diagnostic performance (concordance between predicted and electrophysiologically confirmed AP locations) was evaluated. Operational metrics were compared with a historical control cohort (n=189) managed without the algorithm. RESULTS: All 109 patients (51.4% male, mean age 43.6 ± 14.9 years) presented with a single manifest AP (52 right-sided, 47.7%; 57 left-sided, 52.3%). The overall diagnostic accuracy of the ECG schematic for predicting the correct AP anatomical zone was 92.7% (101/109 cases). The acute procedural success rate was 100%. Right-sided AP ablations showed longer total procedure duration (52.9 ± 21.5 min vs. 44.9 ± 14.5 min, p < 0.05) higher total radiofrequency delivery time (368.1 ± 202.5 sec vs. 261.6 ± 110.6 sec, p < 0.01), and more RF applications (10.9 ± 8.3 vs. 5.7 ± 3.7, p < 0.001) than left-sided APs. Fluoroscopy time did not differ significantly between right- and left-sided groups (7.3 ± 4.2 min vs. 7.0 ± 3.8 min, p > 0.05). Compared with the historical control group (n=189), implementation of the ECG schematic was associated with reductions in total procedure duration (48.7 ± 18.5 min vs. 55.0 ± 29.7 min, p < 0.05) and fluoroscopy exposure (7.2 ± 4.0 min vs. 9.0 ± 5.0 min, p < 0.001). No major adverse cardiovascular events or permanent AV blocks occurred; one minor transient phrenic nerve response (0.9%) resolved spontaneously. CONCLUSION: The pre-procedural surface ECG prediction schematic provides reliable anatomical localization of APs in typical WPW syndrome. Its clinical application was associated with reduced total procedure duration and fluoroscopy exposure time, while maintaining a high acute success rate and a favorable safety profile.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE