RESEARCH / DISCOVERY
← Back to the library

Real-world gait study of Parkinson's disease using wearable sensors: a systematic review.

Real-world gait study of Parkinson's disease using wearable sensors: a systematic review.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Vernon, FR · Author affiliation

Sysnav, 72 rue Emile Loubet, 27200, Vernon, France. michaudmona@gmail.com.
Location evidence

Paris, FR · Author affiliation

Université Paris Saclay, Université Paris Cité, ENS Paris Saclay, CNRS, SSA, INSERM, Centre Borelli, 91190, Gif-sur-Yvette, France. michaudmona@gmail.com.
Location evidence

Gif-sur-Yvette, FR · Author affiliation

Université Paris Saclay, Université Paris Cité, ENS Paris Saclay, CNRS, SSA, INSERM, Centre Borelli, 91190, Gif-sur-Yvette, France. michaudmona@gmail.com.
Location evidence

Clamart, FR · Author affiliation

Service de Chirurgie Orthopédique Traumatologique et Reconstructrice, HIA Percy, SSA, 92140, Clamart, France.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: New technologies, such as wearable sensors, allow the quantitative assessment of gait alterations due to Parkinson's disease (PD) through Digital Mobility Outcomes (DMOs). These DMOs have the potential to complement traditional clinical assessments but must be relevant, reliable, and representative of the patient's overall condition. Real-world monitoring offers a valuable approach for this type of day-to-day evaluation of patients. OBJECTIVE: This systematic review has four primary aims: 1) To identify trends in protocol design for real-world gait monitoring using wearables in patients with PD. 2) To detail the analysis of inertial data and the computation of DMOs. 3) To summarize the clinical scales and symptoms studied. 4) To outline trends in the conclusions and limitations reported by authors in this field. METHODS: Three databases (MEDLINE via PubMed, Cochrane, and EMBASE) were systematically searched between September 1, 2013, and September 15, 2023. Eligibility criteria included studies involving adults with a PD diagnosis, the use of a wearable device with at least one accelerometer or gyroscope, and gait analysis conducted in real-world settings. RESULTS AND CONCLUSION: Sixty-three studies were selected. Overall, wearables successfully provide clinically meaningful information on gait impairment in patients with PD. Stride speed as a DMO is well-established and clinically meaningful, while other metrics, such as stride length, stride duration, and cadence, show great promise for routine clinical practice and research. However, the lack of consensus on the methods of investigation and the small sample sizes remain significant barriers that must be addressed to facilitate broader adoption in clinical practice and research.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE