RESEARCH / DISCOVERY
← Back to the library

Performance of CT-guided spatial normalization for semi-quantification of dopamine transporter SPECT and detection of nigrostriatal degeneration.

Performance of CT-guided spatial normalization for semi-quantification of dopamine transporter SPECT and detection of nigrostriatal degeneration.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Lyon, FR · Author affiliation

Hospices Civils de Lyon, Département de médecine nucléaire, F-69000, Lyon, France.
Location evidence

Bron, FR · Author affiliation

Université Claude Bernard Lyon 1, Centre de Recherche en Neurosciences de Lyon (CRNL), CNRS UMR 5292, INSERM U1028, Bron, France.
Location evidence

Oullins, FR · Author affiliation

Université Claude Bernard Lyon 1, Faculté de Médecine et de Maïeutique Lyon Sud Charles Mérieux, Oullins, France.
Location evidence

Hamburg, DE · Author affiliation

Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVE: The present study aims to assess the performance of a CT-guided spatial normalization method (CT-method) for the anatomical region-of-interest (ROI)-based semi-quantification of dopamine transporter (DAT) single photon emission computed tomography (SPECT) images and the detection of nigrostriatal degeneration as compared to an effective SPECT template-based method (MSPECT-method) and visual analysis performed by an expert reader. METHODS: Patients who underwent [123I]FP-CIT SPECT/CT in the Hospices Civils de Lyon between 2008 and 2018 for clinically uncertain parkinsonian syndromes were included. The proposed CT-method aimed to spatially normalize the jointly acquired CT scans and apply the deformation fields to the coregistered SPECT images. It was compared to an effective SPECT template-based method using multiple templates as target for the spatial normalization (MSPECT-method). The distribution of specific binding ratios (SBR) was compared between both methods and the SBR classifications were compared to an expert’s visual classification of the scans, which served as the reference. RESULTS: Overall, 1156 patients (mean age ± SD = 68.7 ± 11.5; 52.6% male) were included. The CT-method provided a good separation between the normal and reduced SBR, with a higher effect size of the distance between the Gaussians (3.31 vs 3.11) and smaller overlap (6.44% vs 8.96%) compared to the MSPECT-method. Both the CT-method and MSPECT-method demonstrated high classification accuracy (96.7%, 95% CI: 95.7-97.7% vs. 94.6%, 95% CI: 93.3-95.9%), sensitivity (96.0%, CI: 94.3-97.7% vs. 89.7%, CI: 87.1-92.3%), and specificity (97.3%, CI: 96.1-98.6% vs. 98.7%, CI: 97.9-99.6%), respectively. CONCLUSIONS: The proposed CT-guided spatial normalization method for automated semi-quantitative [123I]FP-CIT SPECT analysis is a viable option when CT images are available. It offers objective spatial normalization and provides high accuracy for the detection of nigrostriatal degeneration, closely aligning with an expert’s visual interpretation. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12149-026-02204-1.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE