RESEARCH / DISCOVERY
← Back to the library

Anthracene-Modified Nanoporous Silica Nanoparticles for ATP Detection and Salivary Diagnostics in Parkinson's Disease.

Anthracene-Modified Nanoporous Silica Nanoparticles for ATP Detection and Salivary Diagnostics in Parkinson's Disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Valencia, ES · Author affiliation

Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, Valencia 46022, Spain.
Location evidence

Martorell, ES · Author affiliation

Unidad Mixta de Investigación en Nanomedicina y Sensores, Universitat Politècnica de València, Instituto de Investigación Sanitaria La Fe (IIS La Fe), Avenida Fernando Abril Martorell, 106, Valencia 46026, Spain.
Location evidence

Centro, ES · Author affiliation

Unidad Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades y Nanomedicina, Valencia, Universitat Politècnica de València, Centro de Investigación Príncipe Felipe, Avenida Eduardo Primo Yúfera, 3, Valencia 46012, Spain.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

ATP is an essential biological molecule, and abnormal levels are linked to various diseases. In this study, we developed an optical sensor array consisting of an anthracene-modified MCM-41 mesoporous nanoparticle-based hybrid organic-inorganic material to detect ATP in a TRIS-HCl buffer (pH 7). To create the sensor, we synthesized MCM-41 silica nanoparticles and functionalized them with aminoanthracene and imidazolium-anthracene groups. The fluorescence responses of the optical sensor array were recorded and analyzed by using a pattern recognition protocol, specifically linear discriminant analysis, to distinguish between ATP, ADP, AMP, and potential interferents. Quantitative regression analysis of ATP in TRIS-HCl was performed using artificial neural networks, which yielded an acceptable error rate of 7.8%. The sensor array was also evaluated for discrimination of Parkinson's disease (PD) from healthy controls, based on pattern recognition of ATP-related analytes in saliva samples from 24 patients with PD and 23 healthy controls. The results showed that the MCM-41 mesoporous silica nanoparticle-based sensor array can discriminate PD by pattern recognition with 73.7% sensitivity and 83.3% specificity.