RESEARCH / DISCOVERY
← Back to the library

Resolving spectral overlaps in Anti-Parkinson drug combinations: a green spectrophotometric approach for entacapone determination.

Resolving spectral overlaps in Anti-Parkinson drug combinations: a green spectrophotometric approach for entacapone determination.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Cairo, EG · Author affiliation

Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Future University in Egypt, Cairo, 11835, Egypt.
Location evidence

SA · Author affiliation · country only

Department of Pharmaceutical Chemistry, College of Pharmacy, Jouf University, Sakaka, 72388, Saudi Arabia. mhmdgwd@ju.edu.sa.
Location evidence

EG · Author affiliation · country only

Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Beni-Suef University, Alshaheed Shehata Ahmed Hegazy St., Beni-Suef, 62574, Egypt.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

A selective and eco-friendly spectrophotometric approach was developed for the quantitative determination of entacapone (ENT) in the presence of its co-formulated drugs carbidopa (CAR) and levodopa (LEV) which exhibit severe spectral overlap. Three simple spectrophotometric methods; direct zero-order, factorized dual wavelength, and ratio subtraction coupled with constant multiplication techniques were optimized to enable effective resolution of the ENT spectrum without the need for prior separation or complex mathematical treatment. The proposed approaches demonstrated high selectivity toward ENT in laboratory-prepared mixtures and pharmaceutical dosage forms confirming the successful minimization of interference from CAR and LEV. The proposed methods showed excellent linearity over the concentration range of 1.5-14.0 µg/mL with a correlation coefficient (r) of 0.9998. The limit of detection (LOD) and limit of quantification (LOQ) were 0.226 µg/mL and 0.685 µg/mL, respectively confirming high sensitivity. The methods were validated according to international guidelines and proved suitable for routine quality control analysis. In addition, the environmental impact of the developed methods was comprehensively evaluated using multiple greenness assessment tools such as Analytical Eco-Scale, NEMI, GAPI, and AGREE tools confirming their excellent sustainability profile. In conclusion, the developed spectrophotometric methods provide a simple, accurate, precise, and green alternative for determining entacapone in the presence of spectral similar compounds without the need for separation or sophisticated instrumentation.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE