RESEARCH / DISCOVERY
← Back to the library

Electrocardiographic Artifact Caused by Deep Brain Stimulation Mimicking Atrial Flutter in Patient With Contralateral Pacemaker.

Electrocardiographic Artifact Caused by Deep Brain Stimulation Mimicking Atrial Flutter in Patient With Contralateral Pacemaker.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

New York City, US · Author affiliation

Northwell, New Hyde Park, New York, USA; Northwell Cardiovascular Institute, New York, New York, USA; South Shore University Hospital, Bay Shore, New York, USA.
Location evidence

South Shore, US · Author affiliation

Northwell, New Hyde Park, New York, USA; Northwell Cardiovascular Institute, New York, New York, USA; South Shore University Hospital, Bay Shore, New York, USA.
Location evidence

Bay Shore, US · Author affiliation

Northwell, New Hyde Park, New York, USA; Northwell Cardiovascular Institute, New York, New York, USA; South Shore University Hospital, Bay Shore, New York, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Deep brain stimulation (DBS), used in the management of neurologic movement disorders, can generate electrocardiographic artifacts that mimic atrial arrhythmias. CASE SUMMARY: A 63-year-old man with a history of atrial fibrillation ablation, left bundle branch block, and atrioventricular block status post-cardiac resynchronization therapy pacemaker developed Parkinson disease and underwent right-sided deep brain stimulator implantation. A routine electrocardiogram demonstrated apparent atrial flutter. However, interrogation of his pacemaker confirmed normal sinus rhythm, indicating that the surface electrocardiographic findings represented electrical artifacts from DBS. No interruption in pacemaker function or electromagnetic interference was present on intracardiac monitoring. CONCLUSIONS: DBS electrical output can generate artifacts that closely mimic atrial flutter on surface electrocardiogram. In patients who have both deep brain stimulation and a cardiac implantable electronic device (CIED), confirmation with intracardiac electrograms and device interrogation may be used to avoid misdiagnosis and unnecessary intervention. TAKE-HOME MESSAGES: Recognition of DBS-induced ECG artifact is important to ensure appropriate diagnosis and avoid unnecessary interventions. DBS and CIEDs systems can safely coexist without electrical interference when appropriate safety precautions are observed.