RESEARCH / DISCOVERY
← Back to the library

Accelerating imaging: deep learning for enhanced 123I-ioflupane SPECT efficiency.

Accelerating imaging: deep learning for enhanced 123I-ioflupane SPECT efficiency.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Yokohama, JP · Author affiliation

Department of Radiology, Yokohama City University Hospital, 3-9 Fukuura, Kanazawa-Ward, Yokohama, 2360004, Japan. ishi_y@yokohama-cu.ac.jp.
Location evidence

Seto, JP · Author affiliation

Department of Data Science, Yokohama City University, 2-22 Seto, Kanazawa-Ward, Yokohama, 2360027, Japan.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Conventional 123I-ioflupane dopamine-transporter SPECT requires 25-40 min of acquisition, causing patient discomfort and limiting throughput. This study assessed whether deep-learning (DL) reconstruction can yield diagnostic-quality images from a 5-min scan. METHODS: We retrospectively analysed 207 studies (1035 slices) obtained between April 2018 and June 2020. After cropping to 64 × 64 striatal regions, 600, 185 and 250 images from 120, 37 and 50 patients were used for training, validation and testing. Six convolutional architectures-U-Net (one-five depths), V-Net, U-Net +  + , R2U-Net, Attention U-Net and TransUNet-were trained to translate 5-min into virtual 25-min images. Image quality was assessed with peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM), analysed by Friedman and Dunn-Holm tests. A blinded reader study involved three nuclear medicine physicians grading 50 cases (100 striata) on a four-point scale; agreement with the 25-min consensus was measured by weighted κ and intra-/inter-observer intraclass correlation coefficients (ICC). RESULTS: All DL reconstructions significantly outperformed raw 5-min images in PSNR and SSIM (p < 0.01). The four-layer U-Net achieved the highest quality (PSNR 32.7 ± 1.7 dB, SSIM 0.842 ± 0.069), ≈1.8 dB and 0.13 higher than baseline, and statistically indistinguishable from 25-min images (p > 0.05). Reader concordance improved from fair with baseline (κ = 0.29-0.41) to substantial with the four-layer U-Net (κ = 0.62-0.70); intra-reader ICC was 0.84-0.93 and inter-reader ICC 0.73-0.75. CONCLUSIONS: A compact four-layer U-Net restores diagnostic fidelity to 5-min 123I-ioflupane SPECT, enabling an 80% reduction in scan time without loss of quantitative metrics or interpretability. DL-accelerated protocols may enhance comfort, reduce motion artefacts and increase throughput, warranting prospective multicentre validation.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE