RESEARCH / DISCOVERY
← Back to the library

An algorithmic procedure for measuring deep brain stimulation-induced capsular activation using motor evoked potentials.

An algorithmic procedure for measuring deep brain stimulation-induced capsular activation using motor evoked potentials.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Atlanta, US · Author affiliation

Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, United States of America.
Location evidence

Ann Arbor, US · Author affiliation

Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 30322, United States of America.
Location evidence

St. Louis, US · Author affiliation

Department of Neurosurgery, Washington University, St. Louis, MO 63110, United States of America.
Location evidence

New Brunswick, US · Author affiliation

Department of Neurosurgery, Robert Wood Johnson Medical School, Rutgers University, New Brunswick, NJ 08901, United States of America.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Objective.Effective deep brain stimulation (DBS) treatment for Parkinson's disease requires careful surgical targeting and adjustment of stimulation parameters to avoid motor side effects caused by activation of the internal capsule. Currently, patients must self-report side effects during implantation surgery and device programming-a subjective and inconsistent process that may delay optimized treatment or result in suboptimal therapy. Motor evoked potentials (mEP), the use of electromyography to record DBS-induced muscle activation, offer a promising biomarker for objective motor side effect detection.Approach.We present an automated algorithmic procedure for mEP detection and quantification.Main results.First, we design and evaluate a series of signal processing techniques to accurately detect mEP while mitigating the influence of stimulation artifacts and noise, then demonstrate a strategy for integrating multi-channel EMG responses into a single side effect biomarker (the mEP score). Next, we use data from a large patient cohort of intraoperative recordings (N= 54 subthalamic nucleus (STN) leads) to quantify several physiological features of mEP, including their response frequency, latency, amplitude, and waveform similarity properties. Last, we show that the mEP score responds to DBS amplitude and contact configuration parameters in a manner that is consistent with expected STN-capsular anatomy.Significance.The results of this study inform an end-to-end approach for side effect biomarker measurement that could aid the precision and efficiency of surgical targeting and DBS programming.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE