A clinical grade neurostimulation implant for hierarchical control of physiological activity.
A clinical grade neurostimulation implant for hierarchical control of physiological activity.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Oxford, GB · Author affiliation
Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK.Location evidence
New York City, US · Author affiliation
Feil Family Brain and Mind Research Institute, Weill Cornell Medicine, New York, USA.Location evidence
London, GB · Author affiliation
Academic Neurosurgery Unit, Neuroscience and Cell Biology Research Institute, City St. George's University of London, London, UK.Location evidence
Guildford, GB · Author affiliation
Surrey Sleep Research Centre, University of Surrey, Guildford, UK.Location evidence
Publication status: preprint
A plain-language reading has not been prepared for this paper yet.
Original abstract
Bioelectronic implants for neurostimulation aim to steer disordered neurophysiological processes back towards a healthy state. However, physiology is subject to biological rhythms, including the circadian rhythm and the sleep-wake cycle. These predictable rhythms affect disease symptomatology, biomarkers used in closed-loop therapies, and a physiological system's expected response to stimulation. Therefore, therapeutic devices should incorporate feedforward elements to align algorithm parameters with predictable changes in physiological state, as a parallel of physiological rheostatic control. Here we introduce the DyNeuMo-2c, the first clinical-grade implant capable of delivering closed-loop neurostimulation while flexibly changing its functional configuration according to time of day. The device can chronically measure brain activity and motion state to track potential biomarker patterns in natural, out-of-clinic settings, allowing identification and targeting of patient-specific chronotypes. The system implements a hierarchical control flow, with baseline therapy set by a circadian scheduler, and adaptive policies layered to take effect based on specific biomarkers indicating patient and disease state. Using a benchtop validation setup, we demonstrate that the system has the required capabilities for delivering time-contingent closed-loop therapy in two established clinical use cases: Parkinson's disease and epilepsy. Next, we deploy the system in vivo to deliver closed-loop deep brain stimulation in a healthy non-human primate model of vigilance, highlighting the importance of synchronisation between device operation and physiological state in various conditions (task performance, unconstrained behaviour, and sleep). Time-of-day-dependent adaptation of closed-loop stimulation enabled modulation of both vigilance and behaviour. Overall, the novel device architecture provides a proof-of-concept for delivering time-contingent therapy in chronic therapeutic settings where biological rhythms are of key importance.