RESEARCH / DISCOVERY
← Back to the library

An L-shaped flexible neural implant for chronic ECoG signal acquisition in M2 region of control and Parkinsonian rat models.

An L-shaped flexible neural implant for chronic ECoG signal acquisition in M2 region of control and Parkinsonian rat models.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

IN · Author affiliation · country only

Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science, Bangalore, India.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Neural implants help understand neurological disorders and are actively used to study deep and cortical brain surface regions. Dealing with cortical surface regions is less complicated in clinical therapy than deep brain regions. Researchers are interested in identifying cortical surface region/s for a particular neurological disorder. Rodent models are extensively used in preclinical studies. Usually, microwires, screws, and grid-type implants are used for such studies, but they are not designed for specific rodent brain regions. Since the grids are typically standard in size, in some cases, the craniotomy required to implant the grid will be significantly bigger than the region of interest, which may pose challenges for chronic studies due to infection. Additionally, the grids may block the nearby brain regions in multisite studies, posing difficulty for another device to be implanted. In this study, a novel L-shaped surface neural implant with five electrodes (diameter: 400 μm) spanning a 1 mm × 3 mm area is fabricated using biocompatible Polyimide material for cortical surface studies. The overall thickness of the neural implant is around 25 μm. The average impedance of the electrodes is 18.315 kΩ at 1 kHz. A bilateral craniotomy is performed to place the neural implants in the secondary motor area for subdural chronic electrocorticography (ECoG) signal acquisition in control and hemi parkinsonian rats. After the recovery period, the ECoG signals are acquired using the Open BCI Cyton Daisy Biosensing board for two weeks from the rats.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE