Selective detection of Selegiline in Parkinson's patient urine via CuAAC-mediated fluorescence quenching of Azide-modified carbon dots.
Selective detection of Selegiline in Parkinson's patient urine via CuAAC-mediated fluorescence quenching of Azide-modified carbon dots.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Najrān, SA · Author affiliation
Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Najran University, Najran, Saudi Arabia.Location evidence
Jeddah, SA · Author affiliation
Department of Chemistry, Faculty of Science, University of Jeddah, Jeddah, Saudi Arabia.Location evidence
Riyadh, SA · Author affiliation
Department of Chemistry, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh, 11623, Saudi Arabia.Location evidence
Tabuk, SA · Author affiliation
Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Tabuk, Tabuk 71491, Saudi Arabia.Location evidence
Assiut, EG · Author affiliation
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut, Egypt.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
Selegiline, a selective monoamine oxidase-B inhibitor used in Parkinson's disease treatment, requires accurate detection for therapeutic drug monitoring and optimal dosing. This study presents a novel fluorometric method for selegiline detection based on azide-modified carbon dots that selectively interact with selegiline's terminal alkyne group through copper-catalyzed azide-alkyne cycloaddition (CuAAC). This specific click chemistry reaction results in fluorescence quenching of the carbon dots. The detection mechanism and comprehensive characterization of the azide-modified carbon dots are thoroughly discussed, including their synthesis, optical properties, and interaction behavior with selegiline. The method exhibits excellent analytical performance with good linearity across a wide concentration range of (0.1-80.0 ng/mL) and demonstrates a low limit of detection of 0.041 ng/mL. A selective extraction methodology employing FMOC derivatization coupled with mixed-mode cation exchange (MCX) solid-phase extraction was developed to eliminate amine metabolites and biological interferents while preserving selegiline's tertiary amine structure for selective retention and purification. The method shows high selectivity against interferents and achieves excellent percentage recovery values reaching (96.0-97.0 %) when applied to urine samples. Most importantly, the method was successfully applied to urine samples from Parkinsonism patients, providing a non-invasive route for selegiline determination that offers significant advantages over traditional invasive sampling methods.