RESEARCH / DISCOVERY
← Back to the library

Deep-Learning-Based Automated REM Sleep Detection in Patients With REM Sleep Behavior Disorder: Is It Reliable?

Deep-Learning-Based Automated REM Sleep Detection in Patients With REM Sleep Behavior Disorder: Is It Reliable?

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Seoul, KR · Author affiliation

Department of Neurology, Kyung Hee University Hospital at Gangdong, College of Medicine, Kyung Hee University, Seoul, Korea.
Location evidence

Daejeon, KR · Author affiliation

Life Science Research Institute, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Korea.
Location evidence

Incheon, KR · Author affiliation

Department of Neurology, Incheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND AND PURPOSE: Rapid eye movement (REM) sleep without atonia makes it difficult to detect REM sleep stages using electromyography in patients with REM sleep behavior disorder (RBD). The objectives of this study were to propose an automated REM sleep detector that requires only electroencephalography (EEG) and electrooculography (EOG) data, and to evaluate its performance using real-world polysomnography (PSG) data in RBD patients. METHODS: This multicenter study used 310 PSG datasets obtained from 5 tertiary hospitals. The data were divided into RBD (n=200) and non-RBD (n=110), as well as, into Parkinson's disease (PD) with RBD (n=76), PD without RBD (n=46), idiopathic RBD (iRBD) (n=124), and healthy controls (n=64). An automated computerized REM detection algorithm was implemented using U-Sleep's publicly available pretrained network. RESULTS: The U-Sleep-based REM sleep-detection algorithm correctly identified REM sleep with an area under the receiver operating characteristic curve (AUC) of 0.90±0.14. The classification performance of the REM sleep detector differed significantly between RBD and non-RBD patients (AUC=0.88±0.13 vs. 0.93±0.14, p=0.007). The REM sleep detector accurately classified REM sleep in the order of healthy controls, PD without RBD, iRBD, and PD with RBD, with AUC values of 0.94±0.02, 0.92±0.03, 0.90±0.02, and 0.86±0.02, respectively. CONCLUSIONS: Our U-Sleep-based REM sleep detector based on only EEG and EOG data showed good performance in detecting REM sleep. However, it performed considerably worse in RBD, especially in PD with RBD. Using transfer learning with fine-tuning by expert review, a high-performance REM sleep-detecting system will be realized.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE