A generalizable and open-source algorithm for real-life monitoring of tremor in Parkinson's disease.
A generalizable and open-source algorithm for real-life monitoring of tremor in Parkinson's disease.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Nijmegen, NL · Author affiliation
Department of Neurology, Center of Expertise for Parkinson and Movement Disorders, Radboud University Medical Center, Institute for Brain, Cognition and Behavior, Nijmegen, The Netherlands. Nienke.timmermans@radboudumc.nl.Location evidence
Catania, IT · Author affiliation
Department of Medical, Surgical Sciences and Advanced Technologies G.F. Ingrassia, University of Catania, Catania, Italy.Location evidence
Oxford, GB · Author affiliation
MRC Brain Network Dynamics Unit, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.Location evidence
BR · Author affiliation · country only
Federal University of ABC, São Bernado do Campo, Brazil.Location evidence
London, GB · Author affiliation
Department of Bioengineering, Imperial College London, London, UK.Location evidence
Nottingham, GB · Author affiliation
School of Mathematical Sciences, University of Nottingham, Nottingham, UK.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
Wearable sensors can objectively and continuously monitor daily-life tremor in Parkinson's Disease (PD). We developed an open-source algorithm for real-life monitoring of PD tremor which achieves generalizable performance across different wrist-worn devices. We achieved this using a unique combination of two independent, complementary datasets. The first was a small, but extensively video-labeled gyroscope dataset collected during unscripted activities at home (n = 24 PD; n = 24 controls). We used this to train and validate a logistic regression tremor detector based on cepstral coefficients. The second was a large, unsupervised dataset (n = 517 PD; n = 50 controls, data collected for 2 weeks with a different device), used to externally validate the algorithm. Results show that our algorithm can reliably quantify real-life PD tremor (sensitivity of 0.61 (0.20) and specificity of 0.97 (0.05)). Weekly aggregated tremor time and power showed excellent test-retest reliability and moderate correlation to MDS-UPDRS rest tremor scores. This opens possibilities to support clinical trials and individual tremor management with wearable technology.