RESEARCH / DISCOVERY
← Back to the library

Seeding amplification assay with Universal Control Fluid: Standardized detection of α-synucleinopathies.

Seeding amplification assay with Universal Control Fluid: Standardized detection of α-synucleinopathies.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Copenhagen, DK · Author affiliation

Danish Reference Center for Prion Diseases, Department of Pathology, Copenhagen University Hospital, Copenhagen, Denmark.
Location evidence

Frederiksberg, DK · Author affiliation

Department of Neurology, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark.
Location evidence

Bologna, IT · Author affiliation

IRCCS Istituto delle Scienze Neurologiche di Bologna, Bologna, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Seeding amplification assays, specifically the Real-Time Quaking-Induced Conversion method (RT-QuIC), have shown great diagnostic potential for α-synucleinopathies. Numerous research groups have demonstrated the method's high sensitivity and specificity using cerebrospinal fluid (CSF) samples and various RT-QuIC workflows. However, establishing a uniform and stably performing RT-QuIC protocol remains challenging. To address this, we established an RT-QuIC protocol with a Universal Control Fluid (UCF), which is simple to adopt, performs stably, and allows uniform preparation of both sample and control reactions. Firstly, we adapted and established a published 48-hour RT-QuIC protocol, including the in-house production of recombinant α-synuclein (rec α-syn), and evaluated its sensitivity and specificity through a blinded screening of an 81 CSF sample cohort consisting of Parkinson's disease (PD), dementia with Lewy bodies (DLB), Alzheimer's disease, motor neuron disease, multiple system atrophy, unidentified neurodegenerative diseases, and healthy controls. Additionally, we tested all CSF samples in three volumes to determine which volume provides the best diagnostic accuracy. The established RT-QuIC performs nearly equally well with 7 µL and 15 µL added CSF, resulting in 94% and 94.5% diagnostic accuracy, respectively. Secondly, we developed a UCF solution and tested its performance with the established RT-QuIC protocol. Results indicate that UCF, used in defined volume and concentration, standardizes the preparation of both sample and control reactions without compromising the assay's diagnostic accuracy and provides a stabilizing environment for the reactions, ensuring higher reproducibility. The established RT-QuIC protocol for pathologic α-synuclein detection in PD and DLB CSF samples is highly sensitive (92-96%) and specific (93-96%). Therefore, it is important that its adoption in clinical laboratories is uncomplicated and uniform. RT-QuIC with UCF simplifies, standardizes, and stabilizes the assay's performance and, thus, could be recommended as a standard protocol for accurate detection of α-synucleinopathies.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE