RESEARCH / DISCOVERY
← Back to the library

Test-retest properties of [11C]PXT012253 as a positron emission tomography (PET) radiotracer in healthy human brain: PET imaging of mGlu4.

Test-retest properties of [11C]PXT012253 as a positron emission tomography (PET) radiotracer in healthy human brain: PET imaging of mGlu4.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Stockholm, SE · Author affiliation

Department of Clinical Neuroscience, Karolinska Institutet and Centre for Psychiatry Research, Stockholm County Council, Stockholm, S-17176, Sweden. per.stenkrona@ki.se.
Location evidence

Chongqing, CN · Author affiliation

Department of Psychiatry, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, P. R. China.
Location evidence

Valby, DK · Author affiliation

H. Lundbeck A/S, Ottiliave j, Valby, 2500, Denmark.
Location evidence

Budapest, HU · Author affiliation

Department of Biophysics and Radiation Biology, Semmelweis University HUN-REN TKI, Budapest, 1094, Hungary.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: The metabotropic glutamate receptor 4 (mGlu4) has been proposed as a target for Parkinson’s disease to measure levodopa-induced dyskinesia. [11C]PXT012253 is a PET radioligand for mGlu4 (3.4 nM), previously characterized in non-human primates. We aimed to determine the optimal method for quantification, duration for acquisition, and test-retest reliability of the binding parameters for [11C]PXT012253 in healthy volunteers. RESULTS: Six subjects (4 females) completed. [11C]PXT012253 displayed high uptake and rapid wash-out. Unchanged [11C]PXT012253 at 20 min was 10–20%. VT in subcortical regions was higher than in cortical regions. 2TC provided better fits than 1TC. VT by Logan GA and MA1 analysis correlated with that of 2TC-CM. MA1 showed better identifiability and standard error than Logan. The test-retest metrics in pons, putamen and thalamus showed absolute variability of VT<7% and ICC > 0.93 using the 2TC, Logan and MA1 graphical analyses. Time stability analysis showed that VT values estimated using 63 min of imaging were within 10% of the values obtained with 93 min with all three models. CONCLUSION: [11C]PXT012253 showed a high brain uptake, with rapid washout and metabolism. VT was reliably estimated using 2TC, Logan GA and MA1. The test-retest metrics showed high repeatability, indicating [11C]PXT012253 to be a suitable PET radioligand for mGlu4.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE