RESEARCH / DISCOVERY
← Back to the library

Precision of post-operative localization of deep brain stimulation electrodes.

Precision of post-operative localization of deep brain stimulation electrodes.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Prague, CZ · Author affiliation

Department of Neurology, First Faculty of Medicine, General University Hospital in Prague, Charles University, Kateřinská 30, 120 00, Prague, Czech Republic.
Location evidence

Minneapolis, US · Author affiliation

Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, MN, USA.
Location evidence

Leipzig, DE · Author affiliation

Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Tools for post-operative localization of deep brain stimulation (DBS) electrodes may be of major benefit in the evaluation of the stimulation area. However, little is known about their precision. This study compares 3 different software packages used for DBS electrode localization. T1-weighted MRI images before and after the implantation of the electrodes into the subthalamic nucleus for DBS in 105 Parkinson's disease patients were processed using the pipelines implemented in Lead-DBS, SureTune4, and Brainlab. Euclidean distance between active contacts determined by individual software packages and in repeated processing by the same and by a different operator was calculated. Furthermore, Dice coefficient for overlap of volume of tissue activated (VTA) was determined for Lead-DBS. Medians of Euclidean distances between estimated active contact locations in inter-software package comparison ranged between 1.5 mm and 2 mm. Euclidean distances in within-software package intra- and inter-rater assessments were 0.6-1 mm and 1-1.7 mm, respectively. Median intra- and inter-rater Dice coefficients for VTAs were 0.78 and 0.75, respectively. Since the median distances are close to the size of the target nucleus, any clinical use should be preceded by careful review of the outputs.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE