RESEARCH / DISCOVERY
← Back to the library

Battery Longevity in Deep Brain Stimulation for Parkinson's Disease.

Battery Longevity in Deep Brain Stimulation for Parkinson's Disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Boston, US · Author affiliation

Neurosurgical Service, Institute/Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA, fyazdani@bidmc.harvard.edu.
Location evidence

IL · Author affiliation · country only

Neurosurgical Service, Institute/Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA, fyazdani@bidmc.harvard.edu.
Location evidence

Gonābād, IR · Author affiliation

Gonabad University of Medical Sciences, Gonabad, Iran.
Location evidence

Bryan, US · Author affiliation

Texas A&M College of Medicine, Bryan, Texas, USA.
Location evidence

Chicago, US · Author affiliation

Department of Anesthesiology, Rush University Medical Center, Chicago, Illinois, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: In patients receiving deep brain stimulation (DBS) therapy, the longevity of the implanted pulse generator (IPG) is influenced by multiple factors, including patient diagnosis, therapeutic target, neurostimulator type, number of implanted leads, and stimulation settings. Recent advancements in DBS technology include longer-lived batteries, both standard and rechargeable. This study assessed the estimated IPG longevity of Medtronic, Inc., Percept™ PC neurostimulator in Parkinson's disease (PD) and explores factors associated with IPG lifespan. METHODS: Retrospective analysis of Percept™ devices in 31 PD patients who underwent bilateral DBS targeting either the internal globus pallidus or the subthalamic nucleus (STN). The analysis included demographics, clinical information, stimulation settings, lead locations, and total effective energy delivered (TEED). RESULTS: The median IPG longevity was 75.9 months (51.6-92.3). Among stimulation parameters, frequency demonstrated the strongest inverse correlation with longevity (r = -0.49, p < 0.01), followed by pulse width (r = -0.39, p < 0.01), TEED (r = -0.35, p < 0.01), current amplitude (r = -0.33, p < 0.01), and voltage (r = -0.25, p = 0.04), regardless of laterality. In STN-targeted patients, a significant association was observed between the Z-coordinate of the right lead and the presence of side effects (p = 0.04). Monopolar stimulation on the dominant side showed significantly longer IPG longevity compared to bipolar stimulation (80.6 vs. 49.6 months, p = 0.01). CONCLUSION: Significant negative correlations were observed between longevity and various stimulation parameters regardless of laterality. Monopolar stimulation on the dominant side was associated with increased longevity.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE