RESEARCH / DISCOVERY
← Back to the library

Smartphone Application for Spastic Ataxias Cross-Sectional Validation of a Newly Developed Smartphone App for Remote Monitoring in Spastic Ataxias.

Smartphone Application for Spastic Ataxias Cross-Sectional Validation of a Newly Developed Smartphone App for Remote Monitoring in Spastic Ataxias.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Nijmegen, NL · Author affiliation

Donders Institute for Brain, Cognition and Behaviour, Department of Neurology, Center of Expertise for Parkinson & Movement Disorders, Radboud University Medical Center, Nijmegen, The Netherlands. ilse.willemse@radboudumc.nl.
Location evidence

Bologna, IT · Author affiliation

Department of Electrical, Electronic and Information Engineering "Guglielmo Marconi", University of Bologna, Bologna, Italy.
Location evidence

Tübingen, DE · Author affiliation

Section Computational Sensomotorics, Hertie Institute for Clinical Brain Research, Tübingen, Germany.
Location evidence

Heidelberg, DE · Author affiliation

Division of Neurodegenerative Diseases, Department of Neurology, Heidelberg University Hospital and Faculty of Medicine, Heidelberg, Germany.
Location evidence

DE · Author affiliation · country only

Division Translational Genomics of Neurodegenerative Diseases, Hertie-Institute for Clinical Brain Research and Center of Neurology, Tuebingen University Hospital, Hoppe-Seyler-Str. 3, 72076, Tuebingen, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Effective trial-planning in Spastic ataxias (SPAX) is impeded by the absence of validated outcome measures for detecting longitudinal changes. Digital outcome measures show promise, demonstrating sensitivity to disease severity changes in ataxia and strong correlations with clinical scales. The objective of this study was to develop a smartphone application for SPAX (SPAX-app) to obtain valid digital outcome measures for use in clinical trials. The app contains four tasks assessing gait, standing balance (stance), and finger and hand movements. We carried out a validation study in 22 SPAX patients and 10 controls. Subjects performed the tasks three times during one visit. In parallel, we performed Ambulatory Parkinson's Disease Monitoring (APDM) sensor recordings, Q-motor upper limb assessment, and the Scale for the Assessment and Rating of Ataxia (SARA). Significant correlations were found between the SPAX-app and APDM or Q-motor for step time (r = 0.91), all measures of stance (r = 0.51-0.87) and duration of hand alternation (r = 0.64). No significant correlations were found for variability measures (e.g. standard deviation of step time). All tasks of the SPAX-app, except for stance, can discriminate SPAX from controls and show moderate to high test-retest reliability (ICC 0.67-0.97). Significant correlations were found between SARA and step time (r = 0.70), inter-onset interval in finger tapping (r = 0.57), and duration of hand alternation (r = 0.65). The stance task did not show significant correlations with SARA. With the SPAX-app, we present a set of digital outcome measures for potential use in clinical trials. Longitudinal studies are needed to evaluate whether these measures can track disease progression.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE