RESEARCH / DISCOVERY
← Back to the library

Thalamic Deep Brain Stimulation Versus Magnetic Resonance–Guided Focused Ultrasound in Tremor Patients: A Retrospective Single‐Surgeon Comparison

Thalamic Deep Brain Stimulation Versus Magnetic Resonance–Guided Focused Ultrasound in Tremor Patients: A Retrospective Single‐Surgeon Comparison

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

AbstractBackgroundBilateral deep brain stimulation (DBS) and unilateral magnetic resonance–guided focused ultrasound (MRgFUS), with potential future second‐side treatment targeting the thalamic ventral intermediate nucleus (VIM), are currently the two best‐established interventions for pharmaco‐resistant tremors, but treatment selection is hampered by the lack of comparative evidence.ObjectiveTo provide the first direct within‐center and within‐surgeon comparison between bilateral VIM‐DBS and unilateral VIM‐MRgFUS, applying consistently timed and elaborated efficacy and safety assessements.MethodsIn this retrospective study, we included patients having received bilateral VIM‐DBS (n = 30) or unilateral VIM‐MRgFUS (n = 52) performed by one single neurosurgeon between 2014 and 2022. Efficacy was primarily measured by the improvement of the Washington Heights‐Inwood Genetic Study of Essential Tremor scale in the more affected hand at 6 months. Regarding safety, we compared treatment‐, procedure‐, and hardware‐related adverse events (AEs), graded by impact on activities of daily living (ADLs), and serious AEs (SAEs), retrospectively defined based on prolonged/repeated hospitalizations or persistent symptoms affecting ADLs.ResultsWe found equivalent tremor reduction in the more affected hand (DBS: 62.4% [41.3–87.9] vs. MRgFUS: 69.4% [42.4–77.7]; P = 0.958), but contralateral and axial tremors improved only with bilateral DBS. DBS was associated with a higher rate of procedure‐ and hardware‐related AEs (17% vs. 2%; P = 0.023) but a nonsignificantly lower rate of persistent treatment‐related AEs affecting ADLs at 6 months (7% vs. 13%; P = 0.343). Overall, the rates of SAEs (23.3% vs. 19.2%; P = 0.779) and persistent deficits affecting ADLs at 6 months (10% vs. 13%; P = 0.82) were similar.ConclusionsDespite distinct safety profiles, both interventions produced a similar burden of AEs. Tremor control was equivalent on the more affected side, whereas contralateral and axial tremors improved only after bilateral DBS. © 2025 International Parkinson and Movement Disorder Society.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE