RESEARCH / DISCOVERY
← Back to the library

Comparison of visual interpretation of [I-123] FP-CIT SPECT scans versus reference-based quantitative analysis utilizing a Japanese normal database.

Comparison of visual interpretation of [I-123] FP-CIT SPECT scans versus reference-based quantitative analysis utilizing a Japanese normal database.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Fukushima, JP · Author affiliation

Department of Neuropsychiatry, School of Medicine, Fukushima Medical University, Fukushima, Japan.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVE: Dopamine transporter single-photon emission computed tomography (DAT-SPECT) plays an important role in diagnosing parkinsonism. Recently, a reference-based quantitative analysis utilizing a Japanese normal database for DAT-SPECT was developed. This study aimed to investigate the frequency and trends of cases wherein the analysis- and physician-based diagnoses diverged. METHODS: Two physicians performed an interpretation task twice on 195 DAT-SPECT scans. After assessing intra- and intertester agreements, disagreements were resolved by consensus. For the reference-based quantitative analysis, the calibrated specific binding ratio (cSBR), calibrated asymmetry index (cAI), and Z-scores were measured. Images were grouped according to physician consensus and the negative-positive difference from thresholds (Z-score of less than -2.0 and/or cAI of more than 12.22) as follows: group 1 (physician, normal; quantitative analysis, normal; n  = 70), group 2 (abnormal; normal; n  = 4), group 3 (normal; abnormal; n  = 31), and group 4 (abnormal; abnormal; n  = 90). RESULTS: Median cSBRs and Z-scores decreased in order from group 1 to group 4. Median cAI values increased in the order of groups 1, 3, 2, and 4. Significant differences were observed between groups 1 and 2 for cSBRs and cAIs; groups 2 and 3 for Z-scores; groups 2 and 4 for cSBRs and Z-scores; and groups 1 and 3, 1 and 4, and 3 and 4 for all parameters (Kruskal-Wallis and Steel-Dwass tests). CONCLUSION: In approximately 18% of cases, the visual interpretation of physicians diverged from the reference-based quantitative analysis based on a Japanese normal database. It is crucial to appropriately utilize DAT-SPECT reference-based quantitative analysis as a diagnostic aid.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE