RESEARCH / DISCOVERY
← Back to the library

Low-cost graphite and double-gate FET-based label-free biosensor for dopamine sensing to detect neural diseases.

Low-cost graphite and double-gate FET-based label-free biosensor for dopamine sensing to detect neural diseases.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Patna, IN · Author affiliation

Department of Physics, National Institute of Technology Patna, Bihar India.
Location evidence

Kolkata, IN · Author affiliation

Nextgen Adaptive Systems Group, Department of Electrical Engineering, National Institute of Technology Patna, Bihar India; Department of Electrical Engineering, Heritage Institute of Technology, Kolkata, West Bengal India.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

The manuscript proposes biosensors for detecting different concentrations of neurotransmitters named dopamine, which have a critical role in the human body's neurological, hormonal, and renal systems. In this work, the primary focus is to detect dopamine, whose disorder levels cause many neurological disabilities such as Alzheimer's and Parkinson's disease. In the present work, the simulation of two different structures has been studies: a) a graphite-based structure and b) a double gate TFET structure for detecting dopamine using TCAD Silvaco software. The proposed device utilizes a graphite-based structure with respective work functions of the used materials and studies the change in ON current (ION sensing factor is calculated for simulation study for VGS = 0.8 V). The cavity is increased to 800 µm for graphite-based biosensors for improved sensitivity. The graphite-based biosensors can detect up to 13.3 nM concentration of dopamine. Experimental electrochemical analysis results verify the proposed graphite-based biosensors' sensitivity for different dopamine concentrations. Another double gate field effect transistor (FET) biosensor has also been investigated for the detection of dopamine. The effective dielectric constant has been calculated using Bruggeman's model to check the sensitivity of double gate FET-based sensors for varying dopamine and uric acid concentrations. The sensitivity is increased with the increase of dopamine concentration percentage.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE