RESEARCH / DISCOVERY
← Back to the library

Complex striate-frontal projection and specific frontal gyrus dysfunctions concern with the delusional misidentification syndrome: A case report and literature review.

Complex striate-frontal projection and specific frontal gyrus dysfunctions concern with the delusional misidentification syndrome: A case report and literature review.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Tochigi, JP · Author affiliation

Division of Neurology, Department of Medicine, Jichi Medical University, Tochigi, Japan.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Delusional misidentification, a rare syndrome in which a patient displays persistent delusional misidentification of individuals or objects, occurs in several types of dementia. However, the pathology of delusional misidentification is still unclear, and there was no data pertaining to striate-frontal projection. Here, we report a case of delusional misidentification following frontotemporal dementia in which complex striate-frontal and some specific frontal gyrus dysfunction were observed. In our presented case, delusional misidentification progressed following frontal atrophy. Believing that her actual daughter had been replaced by her niece, her symptoms of delusional misidentification and frontal atrophy progressed in the short term, and social arrangement was necessary three months after the onset. There were no abnormal neurological findings including parkinsonism and general cognitive function test scores were preserved. Validated by dopamine transporter single-photon emission computed tomography, right unilateral striatal uptake decreased significantly without parkinsonism or Parkinson's disease. In addition, of specific concern, functional magnetic resonance images showed left opercular inferior frontal gyrus and right superior frontal gyrus dysfunctions. Our case study highlights complex striate-frontal projection and specific frontal gyrus dysfunctions associated with the pathology of delusional misidentification syndrome.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE